APPENDIX B

DIP SWITCH SETTINGS FOR YOUR PRINTER

All printers must configure to a Centronics type psrallel interface.

ANADEX 95ØØ — 93Ø1

All switches on S—3 must be off. Set switches on S-1 snd S—2 appropriately.

CENTRONICS 739—1

All four switches oust be off.

EPSON MX-7Ø

Shorting plug must be hooked up to the red post for no auto—line feed.

EPSON NX—8Ø; NX—SOFT with Graftrax—8Ø

All switches on S-2 should be off. Dip switch S-l, switch 8 must be on and switch 3 must be off.

EPSON MX-1ØØ

S—2

switch 3 must be off

S—1

switch 6 must be off and switch 8 must be on.

I.D.S.

44ØG — 445G

S—4

switches 5, 6 and 7 Must be off

S—3

switches 6 must be on and switch 7 must be off

Strapping for 44ØG — 445G (locate beside I.D.S. cable connector)

9-6

- busy active when high

11-5

— strobe data on positive edge

14—1 — always remain installed

I.D.S. 46ØG — 56ØG

S-4

switch 5

must be

off and switch on

S—3

switches

6 and 7

off

Strapping for 46ØØ—56ØØ (locate beside I.D.S. cable connector) Must be strapped as shipped.

8—7 installed for parallel

11—4 installed for busy rising high 12—3 installed for negative going strobe

*Note: All switches not mentioned can be set as user desires

—15—