Maintenance.

E N G L I S H

Maintenance.

Replacing Disposable Odor Fighting Dust Bag

Replacing Disposable Odor Fighting Dust Bag WARNING: Unplug cord from electrical outlet before servicing.

BAG REMOVAL:

7Unzip outer bag completely.

8Pull bag cardboard collar to release bag dock door from connector. Bag dock door will hinge downward.

9Gently pull bag cardboard collar upward out of the bag dock. Saniseal® dust seal will close automatically.

BAG INSTALLATION:

10Slide the cardboard collar completely onto bag dock door.

11Firmly push bag dock door with both thumbs on indication point until it snaps.

ENFONCEZ JUSQU’À

ENTENDRE UN BRUIT

PRESIONE HASTA

ESCUCHAR UN

CHASQUIDO DE SUJECIÓN

7

8

9

10

11

Replacing Worn Belt

Replacing Worn Belt WARNING: Unplug cord from electrical outlet before servicing.

12Remove the replacement belt from the storage channel.

13Remove the door by removing the hold down screw located on side of power head.

14Fold door away from the power head and lift it away.

15Remove the belt from the motor drive shaft and brush roll pulley.

16Loop the new belt over the brush roll pulley. Place the opposite end of the belt on the motor drive shaft.

14Replace the door by placing the bottom tab on door into slots located inside power head and pressing the door closed.

13Replace the hold down screw and tighten.

12

13

14

15

16

Adjusting or Replacing Brushroll

Adjusting or Replacing Brushroll WARNING: Unplug cord from electrical outlet before servicing.

Your Oreck Vacuum comes with the brush roll set at the “NORMAL” position for most types of carpets.

When using vacuum primarily on Berber Carpets, you can adjust brushroll to the “SPECIAL” setting for increased performance.

17Remove the base plate by removing 5 screws. Then, remove the belt and brushroll from the housing.

18Rotate both end cards of the brush roll to show “SPECIAL” and replace in the holding channels of the housing.

19Note: The one marked “SPECIAL” has several ribs on top of the end card.

20The brush end card setting marked “NORMAL” has one rib. When rotating bearings, make sure both end card assembly settings are the same and face up when replacing the brushroll.

16Reassemble the belt.

17Reassemble the baseplate.