Cleaning the Electronic Collector Cell:

5

6

Cleaning the Electronic Collector Cell:

6.Oreck’s Assail-A-Cell®cleaner is an excellent way to clean a Collector Cell. Be sure to spray between each Cell plate and cover every surface. Allow product to soak for a few minutes, not allowing it to dry. Rinse thoroughly with water. For extremely heavy deposits, repeat the process.

If you prefer not use Oreck’s Assail-A-Cell®cleaner, you may also decide to soak the Collector Cell in warm water in a kitchen sink or bathtub. Mild dish detergent (powder or liquid) may be added to the water to help break down the dirt on the Collector Cell. The Collector Cell should be allowed to soak for two to three hours.

Tobacco smoke (tar) is especially hard to remove from the Collector Cell. If the Purifier has been cleaning tobacco smoke, the Collector Cell may need to soak longer, or it may need to be cleaned a second time.

In either case, the Collector Cell should be allowed to air dry before re-inserting it. Oreck does not recommend the use of heated or compressed air as part of the drying process.

IMPORTANT: Dry the Collector Cell thoroughly outside of the Air Purifier before reinstalling it into the Air Purifier. Ensure that all areas including corners and areas that may trap water are dry before reinstalling into the Air Purifier.

Replacing The Charcoal Odor Absorber (Optional)

In addition to air purification, your Oreck provides the additional benefit of odor removal. The odor removal function is optional. Your Oreck Air Purifier will continue to remove harmful airborne particles with its permanent Electronic Collector Cell even if you choose not to use the optional Charcoal Odor Absorber.

Odor absorption effectiveness will gradually deteriorate over time unless the Charcoal Odor Absorber is replaced. While every environment is different, Oreck suggests that the Charcoal Odor Absorber be replaced every two months or as needed. IMPORTANT: DO NOT wash the Charcoal Odor Absorber. Replace, if necessary.

Replacing Cell After Cleaning

1.Snap in the Charcoal Odor Absorber (fig. 5).

2.Slide in the Pre-Filter (fig. 6).

3.Slide Collector Cell into cabinet, using handles (fig. 4).

4.Replace front grill. Unit is now ready for operation (fig. 3).

NOTE: An occasional snapping or popping sound (“arcing”) is normal when operating the unit immediately after cleaning the Collector Cell and should stop after a few minutes of operation.

CALL CUSTOMER SERVICE HOT LINE

US:1-800-989-3535 Canada: 1-888-676-7325

Whenever calling, please be sure to have your model and serial number from data plate.

Accessories (Sold Separately)

ITEM

 

PART #

1.

Pre-Filter

7780-8040

2.

Ionizer/Electronic Collector Cell

5510-7064

3.

Charcoal Odor Absorber (Set of 4)

AT4PK7

4.

Oreck’s Assail-A-Cell®cleaner

32358

USA: 800-989-3535

Canada: 888-676-7325

Outside the USA and Canada,

contact your local Oreck Distributor.

5

Page 5
Image 5
Oreck COMPACT AIR PURIFIER Replacing The Charcoal Odor Absorber Optional, Replacing Cell After Cleaning, USA Canada