Oreck XL2300RS To Adjust or Replace Brush, Using A Fresh Air Tab, Bulb Replacement, E N G L I S H

Models: XL2250RS XL2300RS XL2200RS

1 20
Download 20 pages 56.25 Kb
Page 7
Image 7
To Adjust or Replace Brush

E N G L I S H

5. Many times blockage occurs

F

due to a full dust bag

causing dirt to back down

Connector

the air flow system. When

Deflector

that happens, the blockage

Opening

will be at the top of the

 

system, starting in the area

 

To Adjust or Replace Brush

WARNING: Unplug cord from electrical outlet before servicing.

where the dust bag connects

to the connector assembly.

See illustration F.

NOTE: If the above actions do not correct the problem, contact an ORECK authorized service center or call the customer service center. US: 1-800-989-3535

CANADA: 1-888-676-7325

IMPORTANT: On plush and new carpets, stuffing may occur due to excessive fuzz and loose cuttings in the carpet. Stuffing could occur for the first few cleanings until all the loose material is removed. Due to the high efficiency of the cleaner, many older carpets will cause stuffing when the cleaner is first used on them.

Using A Fresh AirTab

Your ORECK XL vacuum cleaner has a special FRESH AIR tab pocket. This light-colored pocket is located inside the vinyl bag in the area where the paper disposable bag attaches to the intake

Rotate and match

bearing assemblies

To determine if the brush is worn, place a firm straight edge across the nozzle opening. If brush bristles do not extend beyond base plate, brush should be adjusted.

Remove the base plate by removing 5 screws. Then, remove the belt and brush roll from the housing.

Rotate both bearing assemblies at ends of brush roll to show “old” and replace in the holding channels in the housing.

NOTE: The bearing assembly setting marked “OLD” has two bars ( l l ) on the top of the assembly. The one marked “NEW” has one bar ( l ). When rotating bearings, make sure both bearing assembly settings are the same and face up when replacing the brush roll.

tube. Insert tablet in pocket.

Reassemble the belt and the base plate and check bristle height above base plate at each end of brush.

Bulb Replacement

WARNING: Unplug cord from electrical outlet before servicing.

Model XL2250 only • Remove lamp housing by removing two (2)

screws in the the top of the lamp housing.

• Pull burned out bulb from holder and replace with new bulb.

• Replace lamp housing by replacing two screws in the top of the lamp housing.

IMPORTANT: Unless the brush is worn as indicated above, both bearings must be in the new position. When rotating, both bearings must be in the old position. Unmatched settings will cause damage to your machine.

If a previous adjustment has already been made and bristle height does not extend above base plate, a new brush assembly should be ordered.

7

Page 7
Image 7
Oreck XL2300RS, XL2200RS, XL2250RS To Adjust or Replace Brush, Using A Fresh Air Tab, Bulb Replacement, E N G L I S H