Oregon Daylight Projection Clock, CP100 user manual

Models: CP100 Daylight Projection Clock

1 2
Download 2 pages 52.5 Kb
Page 1
Image 1
Daylight Projection Clock

Daylight Projection Clock

Model: DP100

USER MANUAL

EN

INTRODUCTION

Thank you for selecting the Oregon ScientificTM daylight projection clock (DP100).

NOTE Please keep this manual handy as you use your new product. It contains practical step-by-step instructions, as well as technical specifications and warnings you should know about.

OVERVIEW

FRONT VIEW

1

2

5

6

3

4Manual background

1.CDS light sensor: Adjusts projection brightness

2.ALARM ON / OFF: Activate / deactivate alarm

3.LCD display: Clock, alarm, calendar and indoor temperature

4.Manual background: Alarm icon

5.IR motion sensors: Snooze; change display mode

6.Projector: Projects time, alarm status and indoor temperature

BACK AND BASE VIEW

1

2

6

3

7

4

8

 

9

5Manual backgroundManual backgroundManual background 10

1.FOCUS: Focus the projected image

2.Temperature sensor and adapter slot

3.CLOCK: Enter clock setting mode

4./ : Increase / decrease setting

5.PROJECTION OFF / CLOCK / AUTO: Select projection mode

6.ALARM: Enter alarm setting mode

7.180° ROTATION: Rotate projection image by 180°

8.°C / °F: Select temp erature unit

9.RESET: Return to default settings

10.CDS ON / OFF: Activate light sensor

GETTING STARTED

ADAPTER

Insert the adapter into the adapter slot as shown.

CLOCK

To set the clock:

1.Press and hold CLOCK for 2 seconds. The setting will blink.

2. Use / to change the setting.

3.Press CLOCK to confirm.

4.The settings order is: 12 / 24 hour format, hour, minute, year, month-day format, month and day.

LCD DISPLAY

Use motion above the IR motion sensors to toggle display mode between:

Clock

Calendar

Alarm

Indoor temperature

NOTE The IR motion sensors range is from 2.5 to 15 cm (1 to 6 in) above the sensor. Any movement outside this

range will not be detected.

ALARM

To set the alarm:

1.Press ALARM or navigate to Alarm display.

2.Press and hold ALARM for 2 seconds to enter alarm setting mode. The setting will blink.

3. Use / to change the setting for hour.

4.Press ALARM to confirm.

5.Repeat steps 3 and 4 to set minute. Manual background appears when the alarm is set.

To silence the alarm:

Use motion above the IR motion sensors to activate the 8-minute SNOOZE feature.

OR

• Press ALARM, CLOCK, or to mute the alarm and automatically activate the alarm again after 24 hours.

To activate / deactivate the alarm:

Press ALARM ON / OFF.

PROJECTION

The ultra-bright LED enables daylight projection of time and temperature information.

To activate projection:

Slide PROJECTION to AUTO or CLOCK.

Slide to AUTO to toggle between current time and indoor temperature.

Slide to CLOCK to project current time only.

To adjust the projection image:

Switch CDS to ON to activate automatic projection dimming.

Press 180° ROTATION to rotate the image by 180°.

Focus the projector image by turning the FOCUS wheel.

NOTE Please take care not to look into the projector. Oregon Scientific will not be held responsible for any results or consequences arising from the misuse of this product.

TEMPERATURE

Press °C / °F to select the temperature display unit.

RESET

To return the unit to the default settings, insert a thin blunt object into the RESET hole.

PRECAUTIONS

This product is engineered to give you years of satisfactory service if you handle it carefully. Here are a few precautions:

Do not cover the ventilation holes. Make sure items that are nearby such as newspapers, tablecloths, curtains etc cannot accidentally cover the ventilation holes.

Placement of this product on wood surfaces with certain types of finishes, such as clear varnish, may result in damage to the finish. Consult the furniture manufacturer’s care instructions for direction as to the types of objects that may safely be placed on the wood surface. Oregon Scientific shall not be responsible for any damage to wood surfaces from contact with this product.

Do not immerse the unit in water. If you spill liquid over it, dry it immediately with a soft, lint-free cloth.

Do not clean the unit with abrasive or corrosive materials. This may scratch the plastic parts and corrode the electronic circuit.

Do not subject the unit to excessive force, shock, dust, temperature or humidity, which may result in malfunction, shorter electronic life span, damaged battery and distorted parts.

Do not tamper with the unit’s internal components. Doing so will invalidate the warranty on the unit and may cause unnecessary damage. The unit contains no user-serviceable parts.

Do not dispose this product as unsorted municipal waste. Collection of such waste separately for special treatment is necessary

Due to printing limitations, the displays shown in this manual may differ from the actual display.

The contents of this manual may not be reproduced without the permission of the manufacturer.

NOTE The technical specifications for this product and the contents of the user manual are subject to change without notice.

SPECIFICATIONS

 

TYPE

DESCRIPTION

Unit dimension

138 x 88 x 44 mm

(H x W x D)

(5.4 x 3.5 x 1.7 in)

Unit weight

523g (18.4 oz)

Clock format

12 / 24-hour

Alarm duration

2 min

Snooze

8 min

Temperature range

0°C to 50°C

 

(32°F to 122°F)

Temperature resolution

1°C (1°F)

Projector rotation angle

+ / - 90°

IR sensor coverage distance

2.5 to 15 cm

 

(1 to 6 in)

Power

DC 5.0V adapter

ABOUT OREGON SCIENTIFIC

Visit our website (www.oregonscientific.com) to learn more about Oregon Scientific products such as digital cameras; MP3 players; children’s electronic learning products and games; projection clocks; health and fitness gear; weather stations; and digital and conference phones. The website also includes contact information for our Customer Care department in case you need to reach us, as well as frequently asked questions and customer downloads.

We hope you will find all the information you need on our website, however if you’re in the US and would like to contact the Oregon Scientific Customer Care department directly, please visit:

www2.oregonscientific.com/service/default.asp

OR

Call 1-800-853-8883.

For international inquiries, please visit: www2.oregonscientific.com/about/international.asp

FCC STATEMENT

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and

(2)This device must accept any interference received, including interference that may cause undesired operation.

WARNING Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

NOTE This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.

This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

Consult the dealer or an experienced radio / TV technician for help.

DECLARATION OF CONFORMITY

The following information is not to be used as contact for support or sales. Please call our customer service number (listed on our website at www.oregonscientific.com), or on the warranty card for this product) for all inquiries instead.

We

 

Name:

Oregon Scientific, Inc.

Address:

19861 SW 95th Ave.,

 

Tualatin, Oregon 97062 USA

Telephone No.:

1-800-853-8883

declare that the product

Product No.:

DP100

Product Name:

Daylight Projection Clock

Manufacturer:

IDT Technology Limited

Address:

Block C, 9/F, Kaiser Estate,

 

Phase 1,41 Man Yue St., Hung

 

Hom, Kowloon, Hong Kong

is in conformity with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference. 2) This device must accept any interference received, including interference that may cause undesired operation.

FR

INTRODUCTION

Merci d’avoir sélectionné l’Horloge à Projection de Jour de Oregon ScientificTM. (Modèle DP100).

REMARQUE Veuillez conserver ce manuel pour toutes références ultérieures. Il contient toutes les instructions pratiques, les caractéristiques techniques et les avertissements à prendre en compte.

VUE D’ENSEMBLE

FACE AVANT

1

2

5

6

3

4Manual background

1.Capteur de lumière CDS: Ajuste la clarté de projection

2.ALARM ON / OFF: Permet d’activer / désactiver l’alarme

3.Affichage LCD: Horloge, alarme, calendrier et température intérieure.

4.Manual background: Icône de l’alarme

5.Capteurs de mouvement infra rouge: Snooze (Rappel d’alarme) ; changement du mode d’affichage

6.Projecteur: Permet de projeter l’heure, l’état de l’alarme et la température intérieure

VUE DE DOS ET VUE INFERIEURE

1

2

6

3

7

4

8

 

9

5Manual backgroundManual backgroundManual background 10

1.FOCUS: Permet de mettre au point l’image du projecteur

2.Capteur de température et prise adaptateur

3.CLOCK: Permet d’entrer dans le mode réglage de l’horloge

4./ : Permet d’augmenter / diminuer les valeurs de réglage.

5.PROJECTION OFF / CLOCK / AUTO: Permet de sélectionner le mode de projection

6.ALARM: Permet d’entrer dans le mode réglage de l’alarme

7.180° ROTATION: Permet de faire tourner l’image à 180°

8.°C / °F: Permet de sélectionner l’unité de mesure de la température

9. RESET: Permet de revenir aux réglages par défaut

10.CDS ON / OFF: Permet d’activer le capteur de lumière

AU COMMENCEMENT

ADAPTATEUR

Branchez l’adaptateur dans la prise adaptateur comme indiqué.

HORLOGE

Pour régler l’horloge :

1.Appuyez et maintenez enfoncée la touche CLOCK pendant 2 secondes. Le réglage clignotera.

2. Utilisez / pour changer le réglage

3.Appuyez sur CLOCK pour confirmer.

4.L’ordre de réglage est le suivant : Format 12/24 heures, heure, minutes, année, format mois/jour, mois et jour.

AFFICHAGE LCD

Utilisez le signe situé au dessus des capteurs de mouvement infra rouge pour alterner entre les modes suivants :

Horloge

Calendrier

Alarme

Température intérieure

REMARQUE La portée des capteurs de mouvement infra rouge est de 2,5 à 15 cm (1 à 6 pouces) au dessus du capteur. Tout mouvement hors de cette portée ne sera pas détecté.

ALARME

Pour régler l’alarme :

1.Appuyez sur ALARM ou entrez dans l’affichage de l’Alarme

2.Appuyez et maintenez enfoncée la touche ALARM pendant 2 secondes pour entrer dans le mode de réglage de l’alarme. Le réglage clignotera.

3. Utilisez

/ pour changer le réglage de l’heure

4.Appuyez sur ALARM pour confirmer.

5.Répétez les étapes 3 et 4 pour régler les minutes Manual background s’affichera une fois l’alarme réglée.

Pour couper le son de l’alarme :

Utilisez le signe situé au dessus des capteurs de mouvement infra rouge pour activer la fonction SNOOZE (rappel d’alarme) de 8 minutes.

OU

• Appuyez sur ALARM, CLOCK, ou pour couper le son de l’alarme et la réactiver automatiquement 24 h plus tard.

Pour activer / désactiver l’alarme :

Appuyez sur ALARM ON / OFF.

PROJECTION

La forte clarté de la diode électroluminescente permet une projection en journée de l’heure et de la température.

Pour activer la projection :

Placez l’encoche PROJECTION sur AUTO ou sur

CLOCK.

Placez l’encoche sur AUTO pour alterner entre l’heure actuelle et la température intérieure.

Placez l’encoche sur CLOCK pour ne projeter que l’heure actuelle.

Pour ajuster l’image projetée :

Placez CDS sur ON pour activer la gradation de projection automatique.

Appuyez sur 180° ROTATION pour faire tourner l’image à 180°.

Tournez la molette FOCUS pour mettre au point l‘image projetée.

REMARQUE Faîtes attention à ne pas regarder dans le projecteur. Oregon Scientific ne sera en aucun cas responsable des conséquences ou résultats découlant de la mauvaise utilisation de ce produit.

TEMPERATURE

Appuyez sur °C / °F pour sélectionner l’unité d’affichage de la température.

DP100 MANUAL (E-F-ES).indd 1 P/N:1/2 086L004396-020 REV1

5/19/06 4:18:37 PM

Page 1
Image 1
Oregon Daylight Projection Clock, CP100 user manual