Oregon Scientific BAR686A Temperature, Specifications, Fcc Statement, Moon Phase, Reset

Models: BAR686A

1 2
Download 2 pages 30.36 Kb
Page 2
Image 2
TEMPERATURE

TEMPERATURE

To toggle temperature unit:

Press °C / °F.

To view outdoor sensors temperature readings: Press CHANNEL.

To auto-scan between sensors:

Press and hold CHANNEL for 2 seconds. Each sensor’s data is displayed for 3 seconds.

To end auto-scan:

Press CHANNEL or MEM.

To toggle between current, minimum and maximum records for the selected sensor:

Press MEM repeatedly.

To clear the records:

Press and hold MEM for 2 seconds.

TEMPERATURE AND PRESSURE TREND

The temperature and pressure trend icons are based on recent sensor readings.

RISING

STEADY

FALLING

 

 

 

ICE WARNING

If the channel 1 sensor falls between 3°C to –2°C (37°F to 28°F), TEMPERATURE AND PRESSURE TREND flashes to warn you that the temperature is approaching freezing.

NOTE The warning will automatically stop if the temperature goes outside the ice-warning range.

HI / LO TEMPERATURE ALARM

An alert can be set to sound if the sensor set to channel 1 records above or below a temperature of your choice.

To set alarm ON/OFF:

1.Press and hold TEMP HI / LO ICE WARNING .

2.Use HI / LO TEMPERATURE ALARM and SPECIFICATIONS to select high / low temperature alarm. Press TEMP HI / LO FCC STATEMENT to confirm.

3.Press DECLARATION OF CONFORMITY / MOON PHASE to set alarm ON / OFF and press TEMP HI / LO RESET to confirm.

4.If alarm has been activated, use PRECAUTIONS and ABOUT OREGON SCIENTIFIC to select the temperature.

5.Press TEMP HI / LO Manual background to confirm.

To silence the hi / lo temperature alarm:

Press any key. The alarm resets automatically and will resound if the hi / lo temperature selected is recorded again.

Do not clean the unit with abrasive or corrosive materials.

Do not tamper with the unit’s internal components. Doing so will invalidate the warranty on the unit and may cause unnecessary damage. The unit contains no user-serviceable parts.

Only use fresh batteries as specified in the user’s instructions. Do not mix new and old batteries.

Due to printing limitations, the displays shown in this manual may differ from the actual display.

The contents of this manual may not be reproduced without the permission of the manufacturer.

NOTE The technical specifications for this product and the contents of the user manual are subject to change without notice.

SPECIFICATIONS

TYPE

DESCRIPTION

MAIN UNIT

 

L x W x H

77 x 126 x 102 mm

 

(3.14 x 5.14 x 4.16 in)

 

 

Weight

183 g (6.46 oz) without batteries

 

 

Temperature unit

°C / °F

Temperature range

-5°C to 50°C (23°F to 122°F)

Resolution

0.1°C (0.2°F)

Clock frequency

WWVB-60 (US)

Synchronization

Auto or disabled

 

 

Signal frequency

433 MHz

 

 

Clock

Auto or manual (disabled)

Humidity range

25% - 95%

Humidity resolution

1%

Memory

Min / Max relative humidity and

 

temperature

Alarm duration

2 minutes

Snooze

8 minutes

Clock display

HH:MM:SS

 

HH:MM: Day of Week

Hour format

12 / 24 hour format

Calendar

MM / DD or DD / MM

 

language selectable:

 

E, F, D, I and S

Power

3 x UM-3 (AA) 1.5 V batteries

REMOTE UNIT

 

L x W x H

92 x 60 x 20 mm

 

(3.6 x 2.4 x 0.8 in)

 

 

Weight

62 g (2.22 ounces)

 

without battery

Transmission range

30 m (100 ft) unobstructed

Temperature Range

-30°C to 60°C

 

(-22°F to 140°F)

Power

2 x UM-4 (AAA) 1.5 V batteries

NOTE We recommend that you use alkaline batteries with this product for longer usage and lithium batteries in temperatures below freezing.

FCC STATEMENT

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.

WARNING Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.

NOTE This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.

This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

Consult the dealer or an experienced radio / TV technician for help.

DECLARATION OF CONFORMITY

The following information is not to be used as contact for support or sales. Please call our customer service number (listed on our website at www.oregonscientific.com), or on the warranty card for this product) for all inquiries instead.

We

 

Name:

Oregon Scientific, Inc.

Address:

19861 SW 95th Ave.,Tualatin,

 

Oregon 97062 USA

Telephone No.:

1-800-853-8883

declare that the product

Product No.:

BAR686A

Product Name:

Wireless Weather Forecaster

 

with Temperature Display and

 

Self - Setting Atomic Clock

Manufacturer:

IDT Technology Limited

MOON PHASE

When calendar is set press Manual background or Manual background to view the moon phase for the next/previous day.

Press and hold Manual background or Manual background to scan through the years (2001 to 2099).

New Moon

Waxing Crescent

First quarter

Waxing Gibbous

Full Moon

Waning Gibbous

Last quarter

Waning Crescent

RESET

Press RESET to return the unit to the default settings.

PRECAUTIONS

This product is engineered to give you years of satisfactory service if you handle it carefully. Here are a few precautions:

Do not subject the unit to excessive force, shock, dust, temperature or humidity, which may result in malfunction, shorter electronic life span, damaged battery and distorted parts.

Do not immerse the unit in water. If you spill liquid over it, dry it immediately with a soft, lint-free cloth.

ABOUT OREGON SCIENTIFIC

Visit our website (www.oregonscientific.com) to learn more about Oregon Scientific products such as digital cameras; MP3 players; children’s electronic learning products and games; projection clocks; health and fitness gear; weather stations; and digital and conference phones. The website also includes contact information for our Customer Care department in case you need to reach us, as well as fre- quently asked questions and customer downloads.

We hope you will find all the information you need on our website, however if you’re in the US and would like to contact the Oregon Scientific Customer Care department directly, please visit: www2.oregonscientific.com/service/default.asp

OR

Call 1-800-853-8883.

For international inquiries, please visit: www2.oregonscientific.com/about/international.asp

Address:

Block C, 9/F, Kaiser Estate,

 

Phase 1,41 Man Yue St.,

 

Hung Hom, Kowloon,

 

Hong Kong

is in conformity with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference. 2) This device must accept any interference received, including interference that may cause undesired operation.

©2006 Oregon Scientific. All rights reserved.

086L004258-017

BAR686_M

2

2005.12.12, 4:37 PM

Page 2
Image 2
Oregon Scientific BAR686A Temperature, Specifications, Fcc Statement, Moon Phase, Reset, Precautions, Ice Warning