Wireless Indoor and
Outdoor Thermometer
with LED Ice Alert
Model: EMR201
USER MANUAL
OVERVIEW
FRONT VIEW
3
��������� 4
1.Remote sensor reception indicator
2.Outdoor temperature
3.Indoor temperature
4.Ice alert LED indicator
BACK VIEW
1
2
1.°C / °F: Select temperature unit
2.RESET: Reset unit to default settings
REMOTE SENSOR
2
1
4
1.LED status indicator
2.Wall mount hole
3.Battery compartment
4.RESET hole
5.CHANNEL switch
GETTING STARTED
INSERT BATTERIES
1.Remove the battery compartment.
2.Insert the batteries, matching the polarities (see FIG 2).
3.Press RESET after each battery change.
LOCATION | MEANING |
Indoor temperature | Main unit batteries low |
area | |
Outdoor temperature | Sensor batteries low |
area | |
REMOTE SENSOR
To set up the sensor:
1.Open the battery compartment (see FIG 3).
2.Select channel 1 then press RESET.
3.Close the battery door.
4.Place the sensor within 30 m (98 ft) of the main unit using the table stand or wall mount.
TIP Ideal placements for the sensor would be in any location on the exterior of the home at a height of not more than 5 ft and which can shield it from direct sunlight or wet conditions for an accurate reading.
NOTE Use alkaline batteries for longer usage and consumer grade lithium batteries in temperatures below freezing.
SENSOR DATA TRANSMISSION
To search for a sensor:
Reset the unit.
The sensor reception icon in the remote sensor area shows the status:
ICON | | DESCRIPTION |
OUT | OUT | Main unit is searching |
| | for sensor(s). |
OUT OUT | OUT OUT | A channel has been |
| | found. |
OUT | | The sensor cannot be |
| found. |
TIP The transmission range may vary depending on many factors. You may need to experiment with various locations to get the best results.
ICE WARNING
If the channel 1 sensor falls between 3°C to -2 °C (37°F to 28°F), LED indicator will flash, and will stop flashing once the temperature is out of this range.
RESET
Press RESET to return to the default settings.
PRECAUTIONS
•Do not subject the unit to excessive force, shock, dust, temperature or humidity.
•Do not cover the ventilation holes with any items such as newspapers, curtains etc.
•Do not immerse the unit in water. If you spill liquid over it, dry it immediately with a soft, lint-free cloth.
•Do not clean the unit with abrasive or corrosive materials.
•Do not tamper with the unit’s internal components. This invalidates the warranty.
•Only use fresh batteries. Do not mix new and old batteries.
•Images shown in this manual may differ from the actual display.
•When disposing of this product, ensure it is collected separately for special treatment.
•Placement of this product on certain types of wood may result in damage to its finish for which Oregon Scientific will not be responsible. Consult the furniture manufacturer’s care instructions for information.
•The contents of this manual may not be reproduced without the permission of the manufacturer.
•Do not dispose old batteries as unsorted municipal waste. Collection of such waste separately for special treatment is necessary.
•Please note that some units are equipped with a battery safety strip. Remove the strip from the battery compartment before first use.
NOTE The technical specifications for this product and the contents of the user manual are subject to change without notice.
SPECIFICATIONS
TYPE | DESCRIPTION |
| |
MAIN UNIT | |
| |
L x W x H | 66 x 27.5 x 87.5 mm |
| (2.59 x 1.08 x 3.44 in) |
| |
Weight | 241 g (8.5 oz) without battery |
| |
Temperature range | -5°C to 50°C (23°F to 122°F) |
| |
Resolution | 0.1°C (0.2°F) |
| |
Signal frequency | 433 MHz |
| |
Humidity range | 25% - 95% |
| |
Humidity resolution | 1% |
| |
Power | 2 x UM-4 (AAA) |
| 1.5 V batteries |
| |
REMOTE UNIT (THN132N) |
| |
L x W x H | 96 x 50 x 22 mm |
| (3.78 x 1.97 x 0.87 in) |
Weight | 62 g (2.22 ounces) |
| |
Transmission range | 30 m (98 ft) unobstructed |
| |
Temperature range | -20°C to 60°C (-4°F to 140°F) |
| |
Power | 1 x UM-3 (AA) 1.5 V batteries |
| |
ABOUT OREGON SCIENTIFIC
Visit our website (www.oregonscientific.com) to learn more about Oregon Scientific products. If you’re in the US and would like to contact our Customer Care department directly, please visit: www2.oregonscientific.com/service/support
OR
Call 1-800-853-8883.
For international inquiries, please visit: www2.oregonscientific.com/about/international
FCC STATEMENT
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1)This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.
WARNING Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
NOTE This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipmentdoescauseharmfulinterferencetoradioor television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
·Reorient or relocate the receiving antenna.
·Increase the separation between the equipment and receiver.
·Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
·Consult the dealer or an experienced radio / TV technician for help.
DECLARATION OF CONFORMITY
The following information is not to be used as contact for support or sales. Please call our customer service number (listed on our website at www.oregonscientific.com, or on the warranty card for this product) for all inquiries instead.
We | |
Name: | Oregon Scientific, Inc. |
Address: | 19861 SW 95th Ave.,Tualatin, |
| Oregon 97062 USA |
Telephone No.: | 1-800-853-8883 |
declare that the product |
Product No.: | EMR201 |
Product Name: | Wireless Indoor and Outdoor |
| Thermometer with LED Ice |
| Alert |
Manufacturer: | IDT Technology Limited |
Address: | Block C, 9/F, Kaiser Estate, |
| Phase 1,41 Man Yue St., |
| Hung Hom, Kowloon, |
| Hong Kong |
is in conformity with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1)This device may not cause harmful interference.
2)This device must accept any interference received, including interference that may cause undesired operation.
©2007 Oregon Scientific. All rights reserved. P/N: 086L005000-011