Image 10
Busy Channel Lock (BCL)

Operation

Busy Channel Lock (BCL)

The BCL prevents you from accidentally transmitting while the channel is in use.

1.Press and hold the MENU button for 2 seconds, the display will show Light

2.Press the MENU button again five times, the display will show bCL

3.Rotate the X control to select between BCL ON and BCL OFF. When BCL is on the display will show BCL

60 Rx channels

The UHF080 has 60 receive only channels which can be programmed from 450MHz to 512MHz in steps of 12.5KHz.

To program a receive channel.

1.Press the 60Rx button, the display will show channel 41 To select a different channel use the Channel control.

2.Press the PRI button, the 450 in the frequency display will start blinking, use the Channel control to select the desired MHz.

3.Press the PRI button, the 000 in the frequency display will start blinking, use the Channel control to select the desired KHz.

4.Press MEM, the frequency is stored to that channel.

Factory Reset

Should it be necessary you can return all the UHF080 settings to the factory defaults to do this.

1.Switch the unit OFF.

2.Press and hold the CALL button.

3.While still holding the CALL button, turn the power switch to ON, this will reset the factory defaults.

Specifications

Specifications

Available Tx Channels

38

Power Output

5 Watts

CTCSS Sub Channels

38 per channel

DCS Codes

104 per channel

Receive only channel Range

450MHz to 512Mhz in 12.5KHz steps

Input Voltage

10VDC to 15VDC

In-line fuse rating

2 Amps

Antenna Impedance

50 Ohms

18

19

Page 10
Image 10
Oricom UHF080 Specifications, Busy Channel Lock BCL, Rx channels, Factory Reset, To program a receive channel, Operation