Operation
Busy Channel Lock (BCL)
The BCL prevents you from accidentally transmitting while the channel is in use.
1.Press and hold the MENU button for 2 seconds, the display will show Light
2.Press the MENU button again five times, the display will show bCL
3.Rotate the X control to select between BCL ON and BCL OFF. When BCL is on the display will show BCL
60 Rx channels
The UHF080 has 60 receive only channels which can be programmed from 450MHz to 512MHz in steps of 12.5KHz.
To program a receive channel.
1.Press the 60Rx button, the display will show channel 41 To select a different channel use the Channel control.
2.Press the PRI button, the 450 in the frequency display will start blinking, use the Channel control to select the desired MHz.
3.Press the PRI button, the 000 in the frequency display will start blinking, use the Channel control to select the desired KHz.
4.Press MEM, the frequency is stored to that channel.
Factory Reset
Should it be necessary you can return all the UHF080 settings to the factory defaults to do this.
1.Switch the unit OFF.
2.Press and hold the CALL button.
3.While still holding the CALL button, turn the power switch to ON, this will reset the factory defaults.
Specifications
Specifications
Available Tx Channels | 38 |
Power Output | 5 Watts |
CTCSS Sub Channels | 38 per channel |
DCS Codes | 104 per channel |
Receive only channel Range | 450MHz to 512Mhz in 12.5KHz steps |
Input Voltage | 10VDC to 15VDC |
2 Amps | |
Antenna Impedance | 50 Ohms |
18 | 19 |