PS1 Specifications

 

 

Sealed Models

 

 

 

PS1-2500

Continuous Power Rating

 

At 40° C

2500 VA

 

 

At 25° C

3000 VA

AC Voltage / Frequency Output

 

 

120 VAC 60 Hz

AC Input Current Maximum

AC Transfer Switch

50 amps AC

 

 

Battery Charger

16 amps AC with automatic back-off

Maximum AC Surge Current

Peak (1 millisecond)

70 amps AC

 

 

RMS (5 seconds)

50 amps AC

Maximum PV Array Wattage

 

 

3300 watts DC stc rating

PV Open Circuit Voltage

 

Maximum

150 VDC

MPPT Input Voltage Range

 

 

44 to 135 VDC

PV Array Ground Fault Protection

 

 

Standard - 80 amp DC

Inverter Efficiency

 

Typical

91% (not CEC Certified)

 

 

Peak

93%

MPPT Efficiency

 

 

98%

Overall System Efficiency

 

Typical

89%

 

 

Peak

92%

Battery Voltage - Nominal

 

 

48 VDC

Minimum / maximum operating range

 

 

40 to 60 VDC

Battery Charge Rate

 

Inverter

35 amps DC

 

 

MX60

60 amps DC

AC Output Voltage Regulation

 

Typical

5%

 

 

Nominal

120 VAC

AC Output Current

 

Inverting

25.0 amps AC

 

 

Selling

20.8 amps AC

Total Harmonic Distortion

 

Inverting

2% VAC THD

 

 

Selling

< 5% current THD per UL1741 conditions

AC Transfer Switch Speed

 

Typical

< 16 Milliseconds

Battery Temperature Sensor

 

 

Included

Operating Temperature Range

 

 

-40° C to 60° C (power derated above 25° C)

Recommended Minimum Energy Storage

 

4 kWHRS at 80% discharge

Recommended Batteries

 

 

Four AGM type 31 or type 27 sealed VRLA

Communications

 

 

Optional MATE system display with RS232 port

Enclosure Materials

 

 

Powder coated aluminum, stainless steel hardware

Mounting

 

 

Wall mount, 16 on center studs

Recommended Mounting Hardware

 

 

5/16 x 2.5” Lag Bolts - three per side minimum

System Enclosure Dimensions (H x W x D)

 

Unit

31.3 x 17.25 x 12.9” (80 x 44 x 33 cm)

 

 

Shipping

40.5 x 20.5 x 17.25” (103 x 52 x 44 cm)

Battery Enclosure Dimensions (H x W x D)

 

Unit

36.25 x 17.25 x 12.55” (92 x 44 x 32 cm)

 

 

Shipping

43.25 x 20.25 x 16.75” (110 x 51 x 43 cm)

System Weight

 

Unit

107 lbs (49 kg)

 

 

Shipping

117 lbs (53 kg)

Battery Enclosure Weight (without batteries)

Unit

29 lbs (13 kg)

 

 

Shipping

47 lbs (21 kg)

Certifications

 

 

ETL certified to the UL1741 standard

Anti-Islanding Measures

 

 

UL1741 compliant

Warranty

 

 

5 year limited repair warranty standard

Field Installed Options

 

 

MATE or MATE2 remote system display

 

 

 

OBAC breakers for additional AC load circuits

 

 

 

OBPV breakers for PV array series string protection

Vented Models

PS1-3000

3000 VA

3600 VA

120 VAC 60 Hz

50 amps AC

20 amps AC with automatic back-off

70 amps AC

50 amps AC

3300 watts DC stc rating

150 VDC

44 to 135 VDC Standard - 80 amp DC 91% (CEC Certified) 93% 98% 89% 92%

48 VDC

40 to 60 VDC

45 amps DC

60 amps DC

5%

120 VAC

30.0amps AC

25.0amps AC 2% VAC THD

< 5% current THD per UL1741 conditions < 16 Milliseconds

Included

-40° C to 60° C (power derated above 25° C)

4 kWHRS at 80% discharge

Four AGM type 31 or type 27 sealed VRLA Optional MATE system display with RS232 port Powder coated aluminum, stainless steel hardware Wall mount, 16" on center studs

5/16 x 2.5” Lag Bolts - three per side minimum

31.3x 17.25 x 12.9” (80 x 44 x 33 cm)

40.5x 20.5 x 17.25” (103 x 52 x 44 cm)

36.25x 17.25 x 12.55” (92 x 44 x 32 cm)

43.25x 20.25 x 16.75” (110 x 51 x 43 cm) 107 lbs (49 kg)

117 lbs (53 kg)

29 lbs (13 kg)

47 lbs (21 kg)

ETL certified to the UL1741 standard UL1741 compliant