Panamax MAX 5300-PMBACK PANEL FEATURES, MAX 5300-PMSPECIFICATIONS, MODEL M5300-PM, Same as

Models: MAX 5300-PM

1 2
Download 2 pages 36.98 Kb
Page 2
Image 2
MAX® 5300-PM BACK PANEL FEATURES

MAX® 5300-PM BACK PANEL FEATURES

1. 15A Main Circuit

2. Outlet Bank 5

3. Outlet Banks 3 and 4

Breaker:

Two switched, high-current outlets controlled by

Each bank features two switched outlets with linear

Automatically opens

the front panel Power Button or the DC Trigger in-

filtration technology (LiFT) controlled by the front

when the current load

put. Bank 5 has a 5 second turn on delay and turns

panel Power Button or the DC Trigger input. Banks

is greater than 15

off immediately upon shutdown. The High Current

3 & 4 will turn on immediately and turn off after a

Amps. Push to reset.

outlets provide power from a low impedance noise

10 second delay. LiFT EMI/RFI noise filtration is

 

 

filtration circuit that does not limit the current to

provided by a two-stage balanced Pi filter which

 

 

your equipment. Its output is noise-isolated from all

also provides noise isolation from all other outlet

 

 

other outlet banks.

banks.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4. Outlet Banks 1 and 2

Each bank features two always-on outlets with linear filtration technology (LiFT). Power will only be turned off under a fault condition. (See specifications for over-voltage and under-voltage thresholds). LiFT EMI/RFI noise filtration is provided by a two-stage balanced Pi filter which also provides noise isolation from all other outlet banks.

5.Universal TV Coaxial Jacks

3pairs of bidirectional protection circuits optimized for satellite, cable, and antenna TV signal lines.

6. Main Power Cord 10ft.

7. Ground Lug:

8. Bank 1 & 2 Indicator

Must be plugged into a

Provides a common

Light

properly wired & grounded

grounding point for

Normally ON, is lit when

3-wire outlet.

equipment with separate

there is power present

 

ground leads.

on the Bank 1 and 2

 

 

receptacles.

MAX® 5300-PM SPECIFICATIONS

9.Voltage Sense Trigger Output

3.5mm (1/8”) Mini-Plug jack. Connecting a trigger wire to the Voltage Sense Output jack will allow the input signal to pass through the M5300-PM to control the startup/shutdown of an additional device.

10.Voltage Sense Trigger Input

3.5mm (1/8”) mono mini-plug. Connect to a remote trigger device that uses a DC output to trigger a startup/shutdown sequence.

11. LAN Jacks

Protection circuits for 10/100 baseT Ethernet lines. For the LAN 2 protected jacks, the incom- ing LAN line MUST be plugged into the LINE jack and the patch cord to the equipment MUST be plugged into the EQUIP jack. For the LAN 1 protected jacks the incoming LAN line must be plugged into the LINE jack and the equipment must be plugged into the gaming jack on the front panel. 8 wire protection, 52V clamping.

12. Phone Jacks

Protection circuits for standard telephone or pay-per-view lines. Phone circuit is autoresetting. Incoming phone cord MUST be plugged into the LINE jack. Patch cords to the equipment (satellite receiver, digital video recorder, telephone, etc.) MUST be plugged into the EQUIP jacks.

General________________________________________________________________

Dimensions

17 in. W x 12.75 in. D x 3.5 in H, (4.1 in. Including feet)

Weight

30 lbs.

AC Power_______________________________________________________________

Line Voltage

120V, 60Hz

Total Current Capacity

15 A

UL1449 Suppression Rating

330V

Protection Modes

L-N, L-G, N-G

Initial Clamping Level

200V

Energy Dissipation

2125 Joules

Peak Impulse Current

72,000 Amps

Catastrophic Surge Circuit

Yes

Thermal Fusing

Yes

Over-voltage shutoff

142 VAC ± 8 VAC

Under-voltage shutoff

90 VAC ± 2 VAC

EMI/RFI Noise Filtration___________________________________________________

Banks 1, 2, 3, 4

80 db, 100 KHz – 2 MHz

Bank 5, High Current Outlets

60 db, 100 KHz – 2 MHz

DC Trigger Input__________________________________________________________

Jacks

3.5mm (1/8”) mono mini-plug

Voltage and Polarity

3 - 24V DC, bidirectional

Current Requirement

4.6 mA @3V, 58 mA @24V

DC Trigger Output________________________________________________________

Pass through

no delay

Positive = Tip, Negative = Ring

 

LAN Circuits_____________________________________________________________

Clamping Level

52V

Connectors

RJ-45

Wires Protected:

8-Wires

USB Circuit_____________________________________________________________

Jacks

USB-A

Power Delivery

500 mA @ 5 VDC

Telco Circuit____________________________________________________________

Fuseless/Auto-resetting

Yes

Clamping Level

260V

Capacitance

30pf (approx.)

Suppression Modes

Metallic & Longitudinal

Wires Protected

2-Wire, Pins 4 & 5

Connectors

RJ-11

Cable and Satellite Circuits________________________________________________

HD 1080 i/p Ready

Yes

Shielded

Yes

Clamping Level

75V

Frequency Range

0 MHz - 2.2 GHz

Insertion Loss

< 0.5 dB

Connections

Female “F”, Gold Plated

Bidirectional

Yes

Design and specifications subject to change without notice due to product improvement.

UPC’S, QUANTITIES, WEIGHTS & MEASUREMENTS FOR ORDERING & SHIPPING

MODEL M5300-PM

 

 

UNIT CARTON

 

 

 

 

 

MASTER CARTON

 

17” x 12.75” x 3.5”

 

30 lbs

23.75” x 18.5” x 10”

 

33.5 Lbs

 

0 50616 00816 7

1

 

Same as

 

33.5 Lbs

 

 

 

 

 

 

 

4.1” H with feet

 

 

 

 

 

 

 

 

 

Unit Carton

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5 00 50616 00816 2

1690 Corporate Circle, Petaluma, CA. 94954 800-472-5555 or 707-283-5900 Fax 707-283-5901 www.panamax.com

© 2007 Panamax, Inc. Panamax, MAX, and the Panamax logo are registered US trademarks of Panamax

L590 REV A 07/07