A Rich Array of Features for More Reliable and Efficient Surveillance

Three Sequencing Features for More Efficient Monitoring

These features allow you to determine the sequence in which you seem images from multiple cameras. System Controller buttons make monitoring more efficient by enabling instant selection of the pattern of your choice.

Tour Sequence

Automatically switches camera images sequentially on the selectedmonitor. Up to 128 patterns can be programmed with as many as 64steps per pattern. Camera preset position (1 ~ 255) and AUX output (1,2) can also be controlled and up to 86,339 seconds dwell time isavailable in each step.

Group Preset

Allows instant spot display of selected camera with preset position (1 ~255) on up to 64 pre-selected monitors at once. Up to 128 patterns canbe programmed.
step 1Tour 1C1Tour 2C5Tour 3C9Tour 128C13step 2C2C6C10C14step 3C3C7C11C15step 64C16C4C8C12The image shifts automatically from one camera to another, as programmed.The images can be seen on any monitor.M1 M64
Alarm ID PriorityAlarm Source Alar m OutputActionNo. Type ID Preset AUXDwell TimeText Target0Camera spot 1 1 1 3sec Entrance 1 Zoom 1 (M1, M2)1Camera spot 2 OFF 5sec Entrance 1 Wide 1 (M1, M2)256 1 Terminal 513 2 Tour SEQ 1 3sec Entrance Area 2 (M11, M12)8Group SEQ 1 4 sec Group level 13 (M31, M32, M33,M34) 9 Text only Entrance 1 Level 1 16 (M63, M64)Alarm Output 513Action 0Camera 1Target 1 M1Action 1Camera 2Target 1 M2Action 2Tour SEQ1Target 2 M11C1M11 M11 M11Action 8Group SEQ1Target 3 M31, 32, 33, 34Action 9TextTarget 16 M63Entrance 1Level 1Camera 1Camera 2Preset Position 1(Zoom in to Entrance 1)TerminalAlarm 256Example: Terminal Alarm Event No.256SensorSystemEntrance 1InfraredSensorWJ-SX650ZOOMSensorC2 C3C1M31C20M32C5M33C15M34
The Matrix System650EX supports flexible alarm handling, up to 1,024 alarm programs and various alarm interfaces including 1,024 terminal inputs, 256 terminal outputs, 512 camera alarms, 512 Video loss alarms and 1,024 serial alarm inputs (Total of terminalinputs and outputs is 1,024). An alarm program can activate up to 10 actions including camera spot, Tour Sequence, Group Sequenceand Text. Each action can be assigned to one of the 16 targets, which includes up to 64 monitors, so that the multiple actions caneffectively be displayed across the alarm target monitors. An alarm terminal output can be triggered when an alarm is activated, acknowledged or reset.
Group Sequence 1Monitor 1step 64step 1 C1Group Sequence 2Group Sequence 128Monitor 2C20Monitor 3C5Monitor 64C15

Group Sequence

Automatically switches Group preset patterns sequentially. Up to 128patterns can be programmed with as many as 64 steps per pattern. Up to 86,339 seconds dwell time is available in each step.
Group Preset 1Monitor 1 Monitor 2 Monitor 3 Monitor 64Group Preset 2Group Preset 128C1 C20 C5 C15
• Alarms can be scheduled by programming the timerevent function. • Alarm priority control enables effective managementfor alarms, timer events and operators.• Up to 1,024 Alarm Program status, up to 100 eventsof Alarm History and up to 100 events of Video-lossHistory can be viewed on a monitor. • Up to 30 days of Alarm logs can be stored in the mainCPU unit.• Alarms can be suspended individually by Arm/Disarmbutton from the system controller.• Hold mode displays first alarm while sequence modedisplays multiple alarms sequentially when multiplealarms are activated.Up to 512 operators can be registered with individual operator IDs, passwords and priority (0 to 65,534). 16 operator levels are fullyconfigurable with numerous parameters such as camera select, alarm select and DVR select. Administrators for the system setup are registered separately, allowing secure user management.The System650EX has flexible system partitioning and priority features allowing for advanced operation management. Partitioning includes Controller to Area, Monitor, Camera view, Camera control, Group Sequence, Alarm, Alarm I/O, Recorder,Operator-to-Controller and Monitor-to-Camera. Priority control includes Operator, Controller, Alarm and Timer-event so that the flexiblepriority control is available. For example, a higher operator will not be bothered by the lower priority alarms or timer events and higherpriority alarms will not be disturbed by the lower priority operators or timer events. In addition, the System650EX can create the Areasincluding Monitors, Controllers, Tour Sequences, Group Presets and Group Sequences. All these items, except controllers, can have alocal number enabling the operators to select them by using a simpler reference number.4 5Event ID Priority Action ID Monitor Start Date Start Time End Date End Time Repeat15Alarm Disarm 11 Nov. 2006 08:00 Daily25Alarm Arm 11 Nov. 2006 17:00 Daily310Camera spot 1 1 11 Nov. 2006 08:00 31 Jan. 2007 17:00 Weekly1,024 20 Tour SEQ 3 4 1 Dec. 2006 09:00 1 Dec. 2006 18:00 Once
MAJOR FUNCTIONS
Controller 1
ID 1-5
Local 1-5
Local -1Physical 11TourController 2Controller priorityOperator priorityOperator to ControllerController-Camera Logical 1AreaCam-MonAREA 1
ID 1-5
Local 1-5
Local -2Physical 12G-Preset
ID 1-5
Local 1-5
Local -3Physical 13G-SEQController 3
ID 6-10
Local 1-5
Local -1Physical 14TourController 4 Controller 5Controller-MonCont-G.SEQAREA 2
ID 6-10
Local 1-5
Local -2Physical 15G-Preset
ID 6-10
Local 1-5
Local -3Physical 16G-SEQLogical 2 Logical 3 Logical 4 Logical 5

Up to 1,024 Alarm Events Ensure That You Capture Vital Scenes

Flexible System Partitioning and Priority

User Management for Preventing Unauthorized Access

Camera spot, Tour Sequence, Group Preset,Group Sequence, Alarm arm/disarm and Modechange features can automatically be activated,following programmed schedules. Up to 1,024timer events can be registered.

Timer Events for Simple, Certain Operation

Level 2Level 1PriorityOPERATOR’S LEVEL TABLE
OPE
2
OPE
6
Password21233
OPE
1
12123
22342
Permission Override
Area Change
ALM Select
ALM Reset (ALL)
ALM Ack/Reset
ALM Arm/Dis (ALL)
ALM Arm/Dis
ALM Status Svc
ALM History Svc
Output Ports
CAM Select
CAM Pos
CAM Preset Prg
CAM Menu On/Off
CAM Function Cds
CAM Receiver
CAM Setup Data
CAM Lock
CAM Lock Override
DVR Select
DVR Ctrl
Tour Sequence
Group Sequence
Group Preset
SEQ Stop (ALL)
SEQ Controller Prg
Video Loss Svc
MON Select
MON Lock
OSD On/Off
Time & Date On/Off
Area Change
ALM Reset (ALL)
ALM Ack/Reset
ALM Arm/Dis
ALM Status Svc
Output Ports
CAM Select
CAM Pos
CAM Menu On/Off
CAM Function Cds
CAM Receiver
CAM Lock
CAM Lock Override
Group Sequence
Group Preset
SEQ Stop (ALL)
Video Loss Svc
MON Select
Time & Date On/Off
ALM Status Svc
CAM Select
CAM Pos
CAM Receiver
CAM Lock
Group Sequence
Group Preset
SEQ Stop (ALL)
MON Select
Time & Date On/Off
CAM Select
CAM Lock
Group Sequence
SEQ Stop (ALL)
Time & Date On/Off
Group Sequence
SEQ Stop (ALL)
Time & Date On/Off
Level 3
OPE
7
OPE
16
31256 34682Level 4
OPE
17
OPE
35
34397 31625Level 16
OPE
500
OPE
512
39262 33681
Operator Registration Example Operator Classes Setup Menu
Setup ExampleController-Camera Partition Setup Menu
Partitioning and Priority Overview
Tour Sequences Setup MenuGroup Presets Setup MenuGroup Sequences Setup Menu