ERROR MESSAGES

When trouble has occurred in the VTR, one of the following messages appears on the tape

counter.

The VTR stops operating when any of the error numbers except E-00 and E-01 is displayed.

Error No.
ā€”
dā€”
E 00
E 01
E 11
E 21
E 31
E 32
E 41
E 42
E 43
E 44
E 51
E 52
E 53
E 61
E 62
E 63
E 64
E 65
E 66
E 67
E 68
E 69
E 70
E 80
Description of error
Condensation has formed.
This appears when the servo has been disengaged for 3 seconds during normal
playback.
This appears when dropouts have been detected for two or more seconds during
normal playback.
The reel base which operates in accordance with the size of the tape has been
locked for more than 2.5 seconds.
The cassette has not moved down even when 4 seconds have elapsed since it was
inserted. Alternatively, the cassette is not ejected even when 4 seconds have
elapsed since the EJECT button was pressed.
The loading operation was not completed within 4 seconds.
The unloading operation was not completed within 4 seconds.
The FG (rotational speed) signal has not been output from the cylinder motor.
The PG (phase) signal has not been output from the cylinder motor.
The rotational speed of the cylinder motor is abnormally high.
The rotational speed of the cylinder motor is abnormally low.
The FG (rotational speed) signal has not been output from the capstan motor.
The rotational speed of the capstan motor is abnormally high.
The rotational speed of the capstan motor is abnormally low.
The supply reel motor has locked up.
The take-up reel motor has locked up.
The rotational speed of the supply reel motor is abnormally high.
The rotational speed of the take-up reel motor is abnormally high.
A tension error has been detected.
The start or end processing operation has not been completed even though 7 or
more seconds have passed.
Communication error between SERVO and AVSYS. There is an error in the data.
Communication error between SERVO and AVSYS. The data has been fixed at
high or low.
An error occurred in communication between SERVO and AVSYS when the power
was turned on.
The fan motor stopped operating.
Trouble has occurred in the supply voltage.
36
d ā€”