Setup Menus
OPERATION menu
| Item |
| Setting |
| |
|
|
|
| Description of setting | |
No. | Superimposed | No. | Superimposed | ||
| |||||
display | display |
| |||
|
|
| |||
|
|
|
|
| |
|
|
|
|
| |
100 | SEARCH SPEED |
|
| For setting the speed at which the tape is to be decelerated when the | |
|
|
|
| search switch on the front panel has been pressed. | |
|
| 0000 | X4.1 | 0: 4.1a normal tape speed | |
|
| 0001 | X8.4 | 1: 8.4a normal tape speed | |
|
|
|
|
| |
101 | SHTL MAX |
|
| For setting the maximum speed in the shuttle mode when the external | |
|
|
|
| controller connected to the | |
|
| 0000 | X8.4 | 0: 8.4a normal tape speed | |
|
| 0001 | X16 | 1: 16a normal tape speed | |
|
| 0002 | X32 | 2: 32a normal tape speed | |
|
|
|
|
| |
102 | FF. REW MAX |
|
| For setting the maximum fast forward and rewind speed. | |
|
| 0000 | X16 | 0: 16a normal tape speed | |
|
| 0001 | X32 | 1: 32a normal tape speed | |
|
| 0002 | X60 | 2: 60a normal tape speed | |
|
|
|
| <Note> | |
|
|
|
| When the 50M mode has been selected as the menu item No.007 (SYS | |
|
|
|
| FORMAT) setting, the tape will run at 32a the normal tape speed even if | |
|
|
|
| 60a has been selected. | |
|
|
|
|
| |
103 | AUDIO MUTE |
|
| For setting the status until the audio signals are output when the unit has | |
|
|
|
| been transferred from the stop mode or search mode to play mode. (This | |
|
|
|
| item functions only with PCM audio signals.) | |
|
| 0000 | OFF | 0: It takes a shorter time until the audio signals are output. | |
|
| 0001 | ON | 1: The audio signals are stabilized before they are output. | |
|
|
|
|
| |
104 | REF ALARM |
|
| For setting whether a warning is to be displayed when the reference video | |
|
|
|
| signal has not been connected. | |
|
| 0000 | OFF | 0: No warning is displayed. | |
|
| 0001 | ON | 1: A warning is displayed (the stop button flashes when there is a warning). | |
|
|
|
|
| |
105 | STOP MODE |
|
| For setting the mode of the digital circuit in the stop mode. | |
|
| 0000 | REC | 0: The digital circuit is set to the REC system. It takes a shorter time for | |
|
|
|
| operation to transfer to the REC mode. | |
|
|
|
| In this case, the | |
|
|
|
| TAPE/EE switch. | |
|
| 0001 | PB | 1: The digital circuit is set to the PB system. It takes a shorter time for | |
|
|
|
| operation to transfer to the playback mode. | |
|
|
|
|
| |
106 | HUMID OPE |
|
| For setting whether to ignore condensation when it has formed and | |
|
|
|
| continue with operation. | |
|
| 0000 | OFF | 0: Unit does not continue to operate when condensation has formed. | |
|
| 0001 | ON | 1: Unit continues to operate when condensation has formed in which case it | |
|
|
|
| cannot be guaranteed that the unit will operate normally. | |
|
|
|
| <Note> | |
|
|
|
| Due to the possibility that the tape may be damaged, this item should | |
|
|
|
| normally be set to 0 (no operation). | |
|
|
|
|
| |
107 | WIDE MODE |
|
| For setting whether to perform recording in the wide mode. | |
|
| 0000 | WIDE | 0: Recording is performed in the wide mode. | |
|
| 0001 | NORMAL | 1: Recording is performed in the 4:3 normal mode. | |
|
|
|
|
| |
108 | AUTO REW |
|
| For setting whether to automatically rewind the tape to the beginning when | |
|
|
|
| the tape end has been detected by a recording, playback or search | |
|
|
|
| operation. | |
|
| 0000 | OFF | 0: The tape is not rewound. | |
|
| 0001 | ON | 1: The tape is rewound to its beginning. | |
|
|
|
|
|
The underlining indicates the factory setting.
30