Setup Menus

OPERATION menu

 

Item

 

Setting

 

 

 

 

 

Description of setting

No.

Superimposed

No.

Superimposed

 

display

display

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100

SEARCH SPEED

 

 

For setting the speed at which the tape is to be decelerated when the

 

 

 

 

search switch on the front panel has been pressed.

 

 

0000

X4.1

0: 4.1a normal tape speed

 

 

0001

X8.4

1: 8.4a normal tape speed

 

 

 

 

 

101

SHTL MAX

 

 

For setting the maximum speed in the shuttle mode when the external

 

 

 

 

controller connected to the 9-pin remote connector is used.

 

 

0000

X8.4

0: 8.4a normal tape speed

 

 

0001

X16

1: 16a normal tape speed

 

 

0002

X32

2: 32a normal tape speed

 

 

 

 

 

102

FF. REW MAX

 

 

For setting the maximum fast forward and rewind speed.

 

 

0000

X16

0: 16a normal tape speed

 

 

0001

X32

1: 32a normal tape speed

 

 

0002

X60

2: 60a normal tape speed

 

 

 

 

<Note>

 

 

 

 

When the 50M mode has been selected as the menu item No.007 (SYS

 

 

 

 

FORMAT) setting, the tape will run at 32a the normal tape speed even if

 

 

 

 

60a has been selected.

 

 

 

 

 

103

AUDIO MUTE

 

 

For setting the status until the audio signals are output when the unit has

 

 

 

 

been transferred from the stop mode or search mode to play mode. (This

 

 

 

 

item functions only with PCM audio signals.)

 

 

0000

OFF

0: It takes a shorter time until the audio signals are output.

 

 

0001

ON

1: The audio signals are stabilized before they are output.

 

 

 

 

 

104

REF ALARM

 

 

For setting whether a warning is to be displayed when the reference video

 

 

 

 

signal has not been connected.

 

 

0000

OFF

0: No warning is displayed.

 

 

0001

ON

1: A warning is displayed (the stop button flashes when there is a warning).

 

 

 

 

 

105

STOP MODE

 

 

For setting the mode of the digital circuit in the stop mode.

 

 

0000

REC

0: The digital circuit is set to the REC system. It takes a shorter time for

 

 

 

 

operation to transfer to the REC mode.

 

 

 

 

In this case, the E-E mode is established regardless of the position of the

 

 

 

 

TAPE/EE switch.

 

 

0001

PB

1: The digital circuit is set to the PB system. It takes a shorter time for

 

 

 

 

operation to transfer to the playback mode.

 

 

 

 

 

106

HUMID OPE

 

 

For setting whether to ignore condensation when it has formed and

 

 

 

 

continue with operation.

 

 

0000

OFF

0: Unit does not continue to operate when condensation has formed.

 

 

0001

ON

1: Unit continues to operate when condensation has formed in which case it

 

 

 

 

cannot be guaranteed that the unit will operate normally.

 

 

 

 

<Note>

 

 

 

 

Due to the possibility that the tape may be damaged, this item should

 

 

 

 

normally be set to 0 (no operation).

 

 

 

 

 

107

WIDE MODE

 

 

For setting whether to perform recording in the wide mode.

 

 

0000

WIDE

0: Recording is performed in the wide mode.

 

 

0001

NORMAL

1: Recording is performed in the 4:3 normal mode.

 

 

 

 

 

108

AUTO REW

 

 

For setting whether to automatically rewind the tape to the beginning when

 

 

 

 

the tape end has been detected by a recording, playback or search

 

 

 

 

operation.

 

 

0000

OFF

0: The tape is not rewound.

 

 

0001

ON

1: The tape is rewound to its beginning.

 

 

 

 

 

The underlining indicates the factory setting.