Controls and their functions

<Connector area>

@SD REF IN connectors and 75-ohm termination switch

These are the input connectors for the SD reference video signals.

Input the NTSC signals with color burst.

To terminate, set the switch to ON.

AHD REF IN connectors and 75-ohm termination switch This is the input connectors for the HD reference video signals. Input tri-level sync signals with positive and negative polarities. To terminate, set the switch to ON.

BHD REF OUT connector

This is the output connector for the HD reference video signals used for external synchronization.

It outputs tri-level sync signals with positive and negative polarities.

The field frequency is synchronized with the input signals. (If no signals are input, the frequency follows the menu setting.)

CSD REF OUT connector

This is the output connector for the NTSC external synchronization signal (black burst signal).

DDIGITAL AUDIO IN/OUT connector

This I/O connector is for digital audio signals which comply with the AES/EBU standard.

ERemote control connectors

The unit can be controlled from an external source by connecting the unit with another unit or an external controller.

There are two remote control connectors, one for IN/OUT uses and the other for OUT uses.

IN/OUT: For connection with an external controller. For connection with deck-to-deck operation.

OUT: For connection with parallel running operations. For use in a loop-through configuration.

FENCODER REMOTE connector

The external encoder/controller is hooked up to this connector when the video output signal and other settings are to be adjusted from an external source.

GRS-232C connector

HPARALLEL REMOTE connector

This is used when operating the unit from an external source.

– 17 –