Setup menus

USER menu

<TAPE PROTECT>

 

Item

 

Setting

 

 

 

 

 

 

 

 

 

 

Description

No.

Superimposed

No.

 

Superimposed

display

 

display

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

400

STILL

0000

 

 

 

0.5s

This selects the time to be taken until the unit goes into the tape

 

TIMER

0001

 

 

 

 

5s

protection mode when it is left standing in the stop or search still

 

 

0002

 

 

 

 

10s

(JOG/VAR/SHTL) mode. (Unit: s = second, min = minute)

 

 

0003

 

 

 

 

20s

 

 

 

0004

 

 

 

 

30s

 

 

 

0005

 

 

 

 

40s

 

 

 

0006

 

 

 

 

50s

 

 

 

0007

 

 

 

1min

 

 

 

0008

 

 

 

2min

 

 

 

 

 

 

 

 

 

 

401

SRC

0000

 

 

STEP

 

This selects the operation during the tape protection mode

 

PROTECT

0001

 

 

HALF

when the unit is left standing in the still status during the

 

 

 

 

 

 

 

 

 

search mode (JOG/VAR/SHTL).

 

 

 

 

 

 

 

 

 

0: STEP FWD.

 

 

 

 

 

 

 

 

 

1: HALF LOADING.

 

 

 

 

 

 

 

 

 

<Note>

 

 

 

 

 

 

 

 

 

When STEP FWD is selected, the unit automatically goes into

 

 

 

 

 

 

 

 

 

the HALF LOADING mode when the total time for which the

 

 

 

 

 

 

 

 

 

unit is left standing in the still status reaches 30 minutes.

 

 

 

 

 

 

 

 

 

 

402

DRUM

0000

 

 

 

OFF

This selects the drum operation in the STANDBY OFF mode.

 

STDBY

0001

 

 

 

 

ON

0: The drum stops rotating.

 

 

 

 

 

 

 

 

 

1: The drum continues rotating.

 

 

 

 

 

 

 

 

403

STOP

0000

 

 

STEP

This selects the operation in the tape protection mode when

 

PROTECT

0001

 

 

HALF

the unit has been left standing in the STOP mode.

 

 

 

 

 

 

 

 

 

0: STEP FWD

 

 

 

 

 

 

 

 

 

1: HALF LOADING

 

 

 

 

 

 

 

 

 

<Note>

 

 

 

 

 

 

 

 

 

When STEP FWD is selected, the unit is automatically

 

 

 

 

 

 

 

 

 

transferred to the HALF LOADING mode when the total time

 

 

 

 

 

 

 

 

 

during which it has been left standing in the STOP mode

 

 

 

 

 

 

 

 

 

reaches 30 minutes.

 

 

 

 

 

 

 

 

 

 

The underline on the setting item denotes the initial setting.

<Note>

The cumulative standby time at the same tape position increases when transmitting programs or otherwise using identical materials repeatedly.

– 64 –