Synchro-scan
-
99.68 Hz
250.0 Hz
492.2 Hz
984.4 Hz
1.969 kHz
3.938 kHz
7.875 kHz
Shutter Speed
OFF
1/100
1/250
1/500
1/1 000
1/2 000
1/4 000
1/10 000
Required luminance ratio
1
2
4
8
16
32
64
160
-41-
#4 CCD Read Out Mode Setting [Field/Frame:
Field/Frame 1/Frame 2]
Field: CCD storage will be by field storage.
Frame 1: Vertical resolution increases in frame stor-
age.
Frame 2: Vertical resolution is raised without
increasing residual images by frame storage
and electronic shutter.
#5 Gain Up Setting [Gain: AGC HIGH / AGC LOW /
0 dB - 30 dB / N/Eye L / N/Eye H]
AGC LOW: The Auto Gain Up control with a maxi-
mum gain increase of about 18 dB adjusts the
luminance automatically.
AGC HIGH: The Auto Gain Up control with a maxi-
mum gain increase of about 30 dB operates. If
the luminance is still insufficient, the Night Eye
also adjusts the luminance automatically.
0 dB: 0 dB should be selected in normal cases.
1 dB - 30 dB: Use this range if sufficient video out-
put cannot be obtained even when the lens iris
is opened in shooting dark scenes.
N/Eye L / N/Eye H (Night Eye L/H): Use this mode
if sufficient video output cannot be obtained
even if 30 dB gain up should be selected.
Night Eye can be selected to any of two (L or H)
levels.
• Only 0 dB, 9 dB, or 18 dB, AGC LOW, AGC HIGH
can be selected in case of using the RCU (RCB).
If the lens iris switch is at MANUAL, when operat-
ing the camera alone or when the iris switch on
the RCU (RCB, Hybrid control panel) is at AUTO,
AGC may not function.
• AGC HIGH when the AGC selection switch on the
hybrid control panel is at AGC.
• 0 dB when the manual gain switch on the hybrid
control panel is at LOW, 9 dB when it is at MID, or
18 dB when it is at HIGH.
Notes
POWER
OPERATE
BAR
CAM
MODE
GAIN AWC
SCENE
FILE
ABC
ATW
A
B
AUTO/AIW
ELC
LOW
MID
MANU
ON SC H
OFF
HIGH AGC
OFF
1 / 100
SHUTTER
ON
OFF
1 .
2 .
3 .
4 .
G/L PHASE
T.PED CABLE COMP
90° 180°
0° 270°
YC
Hybrid Control Panel
AGC