< TROUBLE > |
| < CHECK > |
|
| < REMEDY > |
Does not speed- |
| <CHECK FET.> |
| NO | Repair the contact |
control. | → Even if FET block is defective, it can not be replaced individually. |
|
| or replace switch | |
|
| Replace whole switch block. |
| → | & FET block. |
|
| Remove the FET circuit block and check the lead wire terminals. | Ω ) |
| |
|
| These terminals are open normally when there is an open circuit ( |
| ||
|
| between the green and yellow lead wires, and between the blue and |
|
|
|
|
| yellow lead wires. |
|
|
|
NOTE:
*FET is weak against static electricity.
**The resistance value may be some differences depends on the measurement range.
Does not vibrate |
| <CHECK ANVIL.> | NO | Replace anvil. |
or weakness of | → | Check wear condition of anvil. If no less than 1mm from | → |
|
vibration. |
| the corner at (A) side or 0.5mm from the corner at (B) side, |
|
|
|
| anvil is OK. |
|
|
|
|
|
|
|