-52-

<Optional Card Setting Sub Menu

This sub menu appears when a studio card (AW-PB305 or
AW-PB506) has been inserted into the optional card slot.
1. Zebra Indicator Setting [Zebra: OFF, ON]
This is used to select whether to display the zebra pattern
on the viewfinder.
OFF: The zebra pattern is not displayed on the
viewfinder.
ON: The zebra pattern is displayed on the viewfinder.
2. Zebra Level Setting [Level: 70% to 110%]
This enables the zebra pattern to be displayed so that it
will provide as a general guideline for the luminance level.
It can be set when “ON” has been selected as the
zebra indicator setting.
3. Safety Zone Setting [Safety Zone: OFF, 1, 2, 3, 4, 5]
This is used to select the type of safety zone which is
displayed on the viewfinder. A safety zone is not
displayed when “OFF” is selected.
The safety zone and center marker indicate electrical
positions and, as such, they may be at variance with
their optical positions.
4. EVF Output Setting [EVF Output: Y, CVBS]
This is used to set the signals to be output to the
viewfinder.
Y: The luminance signal is output to the viewfinder.
CVBS: The color signals are output to the viewfinder.
When “CVBS” has been selected as the setting, the
zebra pattern will not be displayed on the viewfinder.
Setting and changing the optional cards
1 –––––
2 ––––––
3 –––––
4 –––––
1
54
3
2
The inside and outside frames denote safety zones of about
90% and about 95%, respectively.