Panasonic RS-232C Query DOT Clock, Query Clock Phase, Query Aspect, 36/49, FIT HV-FIT Through

Models: RS-232C

1 49
Download 49 pages 26.58 Kb
Page 36
Image 36

2.109. Query DOT CLOCK

Hexadecimal

 

02h

51h

 

44h

 

 

43h

 

 

03h

 

 

 

 

 

 

 

 

 

 

Character

 

 

 

Q

 

D

 

 

C

 

 

 

 

 

 

 

 

 

 

 

 

 

Response (Callback)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

In the period when the command can be accepted

 

 

 

 

 

 

 

 

 

 

Hexadecimal

 

02h

*1

 

 

*3

 

*5

 

 

 

03h

 

 

 

 

 

Character

 

 

 

 

 

*2

 

 

*4

 

*6

 

 

 

 

 

 

 

 

 

 

Acceptability

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SECURITY

STANDBY

 

NO SIGNAL

 

AV MUTE

REMOTE

 

 

 

 

 

×

 

 

 

×

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameters (*1,

*2, *3, *4, *5,

*6)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

32

 

 

 

 

 

 

 

 

31

 

 

 

 

30

 

 

Hexadecimal

 

2Dh

 

33h

 

32h

2Dh

 

 

33h

 

31h

2Dh

33h

30h

 

Character

 

 

3

 

2

 

 

 

3

 

1

3

0

 

 

 

 

 

 

 

 

 

30

 

 

 

 

 

 

 

 

 

31

 

 

 

 

32

 

 

Hexadecimal

 

30h

33h

30h

30h

 

33h

 

31h

30h

33h

32h

 

Character

0

 

 

3

 

0

 

0

 

3

1

0

3

2

Note:

Only when the input is COMPUTER1 or COMPUTER2, and still image is displayed, this command is acceptable. In other cases, ER401 is returned.

2.110. Query CLOCK PHASE

Hexadecimal

 

02h

51h

 

43h

 

 

50h

 

 

03h

 

 

 

 

 

 

 

 

 

 

Character

 

 

 

Q

 

C

 

 

P

 

 

 

 

 

 

 

 

 

 

 

 

 

Response (Callback)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

In the period when the command can be accepted

 

 

 

 

 

 

 

 

 

 

Hexadecimal

 

02h

*1

 

 

*3

 

*5

 

 

 

03h

 

 

 

 

 

Character

 

 

 

 

 

*2

 

 

*4

 

*6

 

 

 

 

 

 

 

 

 

 

Acceptability

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SECURITY

STANDBY

 

NO SIGNAL

 

AV MUTE

REMOTE

 

 

 

 

 

×

 

 

 

×

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameters (*1,

*2, *3, *4, *5,

*6)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16

 

 

 

 

 

 

 

 

15

 

 

 

 

14

 

 

Hexadecimal

 

2Dh

 

31h

 

36h

2Dh

 

 

31h

 

36h

2Dh

31h

36h

 

Character

 

 

1

 

6

 

 

 

1

 

6

1

4

 

 

 

 

 

 

 

 

 

14

 

 

 

 

 

 

 

 

 

15

 

 

 

 

16

 

 

Hexadecimal

 

30h

31h

34h

30h

 

31h

 

35h

30h

31h

36h

 

Character

0

 

 

1

 

4

 

0

 

1

5

0

1

6

Note:

This command is acceptable only when the input is COMPUTER1 or COMPUTER2. In other cases, ER401 is returned.

2.111. Query ASPECT

Hexadecimal 02h 51h 53h 31h 03h

CharacterQ S 1

Response (Callback)

In the period when the command can be accepted

Hexadecimal 02h *1 03h

Character*2

Acceptability

SECURITY STANDBY NO SIGNAL AV MUTE REMOTE

 

×

 

 

 

×

 

 

 

 

 

 

Parameters (*1, *2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F300 series

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AUTO

4:3

 

16:9

 

S4:3

 

THROUGH

 

 

 

 

Hexadecimal

30h

31h

 

32h

 

33h

 

 

34h

 

 

 

 

Character

0

 

1

 

 

2

 

 

3

 

 

4

 

 

 

 

FW300 series

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AUTO

4:3

16:9

H-FIT

V-FIT

HV-FIT

THROUGH

 

Hexadecimal

 

30h

 

31h

 

32h

 

33h

 

34h

 

35h

 

36h

 

Character

 

0

 

1

 

2

 

3

4

 

5

 

 

6

36/49

Page 36
Image 36
Panasonic RS-232C specifications Query DOT Clock, Query Clock Phase, Query Aspect, 36/49, FIT HV-FIT Through