C. Thermal Fuse

SR-GA421/SR-GA281/SR-GA721

2. FUNCTION OF CENTER THERMOSTAT AND THERMALFUSE

C. Thermal Fuse

The thermal fuse is used to open the circuit to the cooking heater when the temperature has gone unusually high. This happens in cases such as incomplete contact between the heater and pan or if the switch buttons is forced to stay on keeping the heater energized abnormally.

This fuse is not a resetting device and must be replaced after openning.

Whenever replacing the fuse make sure the protective cover is placed over all exposed wiring.

Cause of Fusion

[A] Improper contract between heater and pan

Cause

Remedy

Pan collar or deformed

Foreign matter adhering

Body dented or deformed

Pan bottom dented or

Heater surface deformed

 

 

deformed

or corroded

Remove foreign matter

Repair or replace body.

Replace pan.

Replace cooking heater.

by of (-) screw-driver,

 

 

 

etc., and then polish with

 

 

 

= 320 water paper while

 

 

 

wetting it with water.

 

 

 

[B] Forced application of current

Cause

Remedy

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Chopstick, wooden

Switch lever deformed

piece, etc. inserted onto

or maladjusted, causing

cooking button. (continu-

continuous application of

ous application of current)

current.

Inserted to prevent ear-

Repair or replace parts.

lier turning off? Refer to

 

 

 

 

 

cause in (a) above.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

When fusion takes place, check the cause, set right the faulty section, and be sure to use replacement parts.