5-13825-A2-GB30-20 November 1996
Remote AccessOverview 5-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Remote Access 5-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Overview
The
Remote Access feature of 3800
Plus
modems
allows you to change configuration options and control
test functions in a remote 3825Plus modem from any
COMSPHERE 3800, 3800Plus, or 3900 Series modem
with a Diagnostic Control Panel (DCP). Remote DCP
access is only available when using V
.34, V.32terbo,
V.32bis, or V
.32 modulation schemes.
Remote Access
The following conditions must be met before using the
Remote Access feature:
•A connection using either the dial network or
leased lines must be established.
•The Access from Remote configuration option must
be enabled in the remote 3825Plus modem
(S55 = 0).
•
The Remote Access Password configuration option
must be the same for both the local and remote
modems (S56–S59).
Remote DCP access is accomplished using either the
primary or secondary channel of the VF line. Using the
primary channel gives a much faster response time due to
the higher data rate, but it also interrupts data flow
because primary data is stopped when Remote mode is
active. Once Remote mode is terminated, the primary
channel is automatically made available to data
transmission.
Unlike primary channel communications, the
secondary channel operates at a slower data rate and does
not interrupt data flow.
T
o access the Remote branch of the COMSPHERE
modem menu structure, make the following selections:
Press the
key until Remote appears. Select
Remote.
F1
Online : 28.8 <
Control Remote
F2 F3
To
operate over the secondary channel, press any
function key to select the secondary channel.
F1
Select Channel >
Secondary
F2 F3
To operate over the primary channel, press the
key until Prim appears, and press any function key.
F1
Select Channel <
Prim (data blckd)
F2 F3
5