  Page 43   
C. Troubleshooting 
a. Reset Button.  A manual reset switch is located on the LED end of the 
iSCSI Bridge. On the iS520 (pictured below) and the iS550 (Rack 
Mountable version) this switch is accessible through a pinhole on the 
panel.  By pressing this button momentarily, the user can fully reboot the 
unit while maintaining previous user configuration data.  By pressing and 
holding the button for 15 seconds, the unit will reboot and reset to factory 
default configuration settings.  If you wish to modify settings after the 
reset, you will need to re-login. 
b. SCSI LED Pulsing.  If there are no SCSI targets connected to the iS5xx 
iSCSI Bridge by the time the unit fully boots, the “SCSI” LED will 
constantly pulse.  In this case, turn off all SCSI devices and the iS5xx 
iSCSI Bridge.  Check to see that the  SCSI cables are connected and the 
termination is properly placed.  If a problem is found, resolve the issue 
and power the SCSI devices first and wait for them to be ready.  Then 
power the iS5xx iSCSI Bridge. 
c. Diagnostic Page.  On the Diagnostic page of the Web-based Utility there 
is an “iS5xx Boot Process Status Codes” section.  If the “Processor 
Initialization”, “Network Initialization”, “Web Server Initialization”, 
“SCSI Initialization” or the “iSCSI Initialization” do NOT display an 
“OK” status, reseat the power connector and reboot the unit. 
d. Status and Power LEDs.  The Status and Power LEDs should turn solid 
green after 1 minute of the unit being powered.  If this does NOT occur, 
make sure the power connectors are properly seated and reboot the unit. 
e. Bridge Not Addressable.  If you are not able to communicate with 
Paralan’s iS5xx iSCSI Bridge from your Management/iSCSI Host 
computer, check your IP settings.  Changing IP Addresses, Subnet masks, 
Gateways, iSCSI Protocol port, and Web port on the Bridge may render it