Unpacking Your Model 2125 v.2 & Placement Guidelines

Unpacking Your Model 2125 v.2

Carefully remove your Model 2125 v.2 from its shipping carton and locate the enclosed accessories:

AC power cord

Two 12V DC trigger wires with mono plugs, one with 3.5 mm (1/8‖) mini plugs, one with a 2.5mm sub-mini plug and a 3.5mm mini plug

While you are unpacking your Model 2125 v.2, inspect it thoroughly for possible shipping damage and tell your Parasound dealer immediately if you find any evidence of shipping damage. This would be a good time to make a copy of your sales receipt to store with the Model 2125 v.2’s original packing.

Note: Please save and store both the inner and outer cartons and, most especially, the foam packing inserts to protect the Model 2125 v.2 if you have to move it or ship it. You may wish to flatten the cardboard cartons to save room in storage after cutting the taped seams on the bottom flaps.

Placement Guidelines

The Model 2125 v.2 will be easier to use and will last longer if you follow these simple guidelines:

Place the Model 2125 v.2 on a surface that will adequately support its substantial weight.

Use input and output cables that are long enough to leave some slack; that will enable you to pull the Model 2125 v.2 out of a cabinet to check or to change connections without inadvertently disconnecting cables.

The Model 2125 v.2 should never be placed in a completely enclosed cabinet

Place your Model 2125 v.2 where you can route input and output signal cables as far as possible from any AC cords.

Where signal cables must cross AC cords they should do so only at a 90° right angle.

Ventilation Requirements

Always position the Model 2125 v.2 horizontally.

The Model 2125 v.2 should never be stacked immediately on top of another power amplifier.

Do not install the Model 2125 v.2 in an unventilated equipment cabinet or compartment. Pockets of stagnant hot air can build up even in a cabinet with an open front and back.

Rack Mounting Your Parasound Model 2125 v.2

The Model 2125 v.2 front panel occupies two rack spaces in a standard 19‖ equipment rack.

For rack mounting, you’ll need to use the Parasound RMK22 rack mounting kit (purchased separately). We recommend that you use the 8 insulated shoulder washers with the four mounting bolts which are included with the RMK22. Position these washers on both sides so they ―sandwich‖ the front panel before the mounting bolts are screwed into the rack rail. This will eliminate metal-to-metal contact between the Model 2125 v.2 chassis, the equipment rack, and the other components in the rack.

Note: Tighten each bolt just enough to keep the unit secure in the rack to avoid deforming the shoulder washers. Eliminating metal-to-metal contact reduces the likelihood of creating a ground loop that might introduce hum into your system.

A single standard rack space is 1-3⁄4" (44mm) high in a 19" wide equipment rack. This measurement standard was developed by the EIA (Electronic Industries Association) so manufacturers of electronic components and equipment racks could build products in standardized heights that would fit in a uniform space. Please call your Parasound dealer or Parasound Technical Services if you need additional advice about rack mounting the Model 2125 v.2.