b)To avoid the danger of injury, burning and damage to health:

DANGER OF BURNS! The glue and the nozzle can reach tempera- tures of 200 °C. Do not touch the nozzle or the glue. Keep other people and ani- mals away from the hot glue. On contact with the skin, hold the affected part under running cold water for several minutes. Do not try to remove the glue from the skin.

4.Careful handling and use of electrical power tools

a)Pull the mains plug from the socket before you make any adjustments to the device, change accessories or when the device is put away. This precaution is intended to prevent you from unintentionally starting the device.

b)When not in use always ensure that electrical power tools are kept out of reach of children. Do not let anyone use the device if he or she is not familiar with it or has not read the instructions and advice. Electrical power tools are dangerous when they are used by inexperienced people. Let the device cool down completely before putting it away. The hot nozzle can cause damage.

c)Look after the device carefully. Check that moving parts are working prop- erly and move freely. Check for any parts that are broken or damaged enough to detrimentally affect the functioning of the device. Have dam- aged parts repaired before you use the device. Many accidents have their origins in poorly maintained electrical power tools.

d)Always work with the mains lead leading away from the rear of the device.

Operation

Before first use

Preparing the glue site:

Do not use inflammable solvents to clean the glue site.

The ambient temperature and temperature of the materials to be glued must be not less than + 5° C and not warmer than + 50° C.

The glue sites must be clean, dry and free of grease.

Smooth surfaces should be roughened before gluing.

Warm any materials that are prone to cool down quickly (e.g. steel) to improve the bond with the glue.

Screw on the appropriate nozzle 8 and fit the wire stand 6 .

Preparing the tool for use

Working with the mains lead connected:

1.Connect the mains lead 11 to the glue gun connection 10 (see Fig. F).

Insert the mains plug into the mains socket.

2.Fold forward the wire stand 6 . Stand the device up.

3.Push a glue stick into the feed channel 1 .

4.Let the device heat up for about 4 minutes. The device is now ready for use.

Cordless working:

1.Connect the mains lead 11 to the charger connection 3 .

Insert the mains plug into the mains socket.

2.Place the glue gun into the charger 4 .

3.Push a glue stick into the feed channel 1 .

4.Let the device heat up for about 4 minutes. The device is now ready for use.

5.Repeat the heating-up procedure if the feed switch becomes stiff or the outcoming glue becomes viscous.