Patton electronic 2036, 2037 user manual Dip Switch Summary Table

Models: 2037 2036

1 8
Download 8 pages 61.28 Kb
Page 4
Image 4
DIP SWITCH SUMMARY TABLE

DIP SWITCH SUMMARY TABLE

Position

Function

Factory Default

SW1

Flow Control

Off

Hardware

 

 

 

 

 

SW2

LED Indicator

On

 

Enabled

SW3

Data, Parity, Stop Bits

Off

} 8B, NP, 1S

SW4

Data, Parity, Stop Bits

Off

SW5

Data, Parity, Stop Bits

Off

SW6

Data Rate

Off

}

 

SW7

Data Rate

Off

38400 bps

SW8

Data Rate

Off

 

3.2 DETAILED SWITCH SETTINGS

This section provides detailed information about the function of each DIP switch and lists all possible settings.

Switch 1: Hardware/Software Control

The setting for Switch 1 determines whether these interface converters will control either hardware or software flow control.

Flow Control SW1

Hardware

OFF

Software

ON

Switch 2: Enable/Disable LED Indicator

The setting for Switch 2 determines whether the LED indicator is enabled or disabled.

 

 

LED

SW2

Enabled

ON

 

 

Disabled

OFF

 

 

 

 

Switch 3 through 5: Data, Parity and Stop Bit

Switches 3 through 5 are used to specify the data, parity and stop bits. The following table shows the settings that may be used:

 

 

Stop

 

 

 

Data

Parity

Bit

SW3

SW4

SW5

 

 

 

 

 

 

7B

EP

1S

ON

ON

ON

7B

OP

1S

OFF

ON

ON

7B

NP

2S

ON

OFF

ON

7B

EP

2S

OFF

OFF

ON

7B

OP

2S

ON

ON

OFF

8B

EP

1S

OFF

ON

OFF

8B

OP

1S

ON

OFF

OFF

8B

NP

1S

OFF

OFF

OFF

 

 

 

 

 

 

Switches 6 through 8: Frequency and Data Rate

Switches 6 through 8 determine the frequency and data rate. The following chart shows the settings that may be used:

Model 2036 and 2037

Data Rate

SW6

SW7

SW8

 

 

 

 

1200

OFF

OFF

ON

2400

ON

OFF

ON

4800

ON

ON

OFF

9600

OFF

ON

ON

19200

ON

ON

ON

38400

OFF

OFF

OFF

57600

ON

OFF

OFF

115200

OFF

ON

OFF

 

 

 

 

5

6

Page 4
Image 4
Patton electronic 2036, 2037 user manual Dip Switch Summary Table