Tx1s If the remote Model 2701RC responds to the local Model 2701RCs terminate loopback request, the local unit then sends an all ones pattern before returning to the Idle state
TxP The Model 2701RC is sending a test pattern while in Test Mode
IdlP The Model 2701RC is sending a test pattern in place of data. The Model 2701RC is not in test mode.
The Model 2701RC receiving a RL can be in one of the following states:
RxPr The Model 2701RC is receiving a preparatory pattern.
Sack The Model 2701RC, upon receiving a preparatory pat- tern, sends an acknowledgement message.
RL The Model 2701RC is in remote loopback mode.
RxTr The Model 2701RC is receiving a terminate loopback message.
WE1s The Model 2701RC is waiting for a sequence of all ones and will time out if it does not receive it.
IdleP The Model 2701RC is sending a QRSS, 511 or 2047 pat- tern.
Off The Model 2701RC is in local loopback.
cRDL Type: V.54 (default)
Options: V.54 or CSU
The user can set this switch to select the type of remote loop that will be initiated by the Model 2701. If set to V.54, the Model 2701 will initiate a V.54 loop when Remote Loop is selected by the front panel switches. If set to CSU, the Model 2701 will initiate a CSU loop when Remote Loop is selected by the front panel switches.
RDL Type | |
Off | Initiate a V.54 RDL loop when selected |
On | Initiate a CSU loopback when selected |
29
dTest Pattern Idle (default) Options: Idle or Sending
To send a pattern, press the ‘c’ key and press <spacebar> to send the test pattern. The “OK” message indicates the received test pattern is
Idle Indicates that Model 2701RC is not sending a pattern.
Sending
Indicates that Model 2701RC is sending a pattern.
eError Insertion Off (default) Options: On, Off
You may inject intentional errors into the test pattern by turning Error Insertion ON. The Error (ERR) LED will blink once per second.
fSelected Pattern
Options: QRSS, 511, or 2047
Use this option to select the test pattern used to test the link.
NI STATUS
The Network interface (NI) status is shown in the middle of the Diagnostics/Statistics screen. The brackets
are empty when the link is operating normal- ly. Only one error message is provided.
Receiver Carrier Loss [RCL] occurs when 255 consecutive zeros have been detected at the network interface. RCL clears when a pulse is detected.
Current DIP Switch Settings
The Switch settings are displayed here to facilitate troubleshooting your unit without opening up the unit first.
30