3.2.4 Unit Options
The Unit Options screen looks like this (factory default):
aHeader Line 1 &
bHeader Line 2
Headers 1 and 2 are provided for easy identification of your unit after installation. You may want to give each unit a unique name via the header lines to help distinguish one unit from another. You can enter a header up to 40 letters long. Two lines provide 80 letters for your use. That’s a lot of flexibility!
Password
The Password facility provides security by allowing only those who know the correct password to configure the unit via the control port. You can still configure the unit via the DIP switches. The password can be up to 16 characters long, with no restriction on the combination of characters you can use, so be sure to remember the password. The password is case sensitive. If you lose your password, you will lose the ability to access the unit via the control port.
dLoop Timeout
The Loop Timeout setting can be set to one of the following:
00:05 = | five minutes |
00:10 = | ten minutes |
00:15 = | fifteen minutes |
00:30 = | thirty minutes (default setting) |
00:45 = | |
01:00 = | one hour |
01:30 = | 90 minutes |
02:00 = | two hours |
03:00 = | three hours |
NEVER = | |
| intervention. |
eTx Data Clock: Internal Tx Clock (default)
Options: Internal Tx Clock or External Tx Clock
Switch
Tx Clock Select | |
Off | Transmit data accept with respect to the transmit |
| clock from the 2701RC |
On | Transmit data accept with respect to the external |
| clock from the DTE |
fSet to Default Configuration
You may set the Model 2701RC to its factory default configuration, except for the header lines and the password, by executing the Set to Default Configuration command.