Patton electronic Standard Model 531 MF, T-Splitter Model 531 MFF, Insta L L At I O N

Models: 531

1 4
Download 4 pages 19.17 Kb
Page 3
Image 3
3.0 INSTA L L AT I O N

3.0 INSTA L L AT I O N

Patton's Model 531 units are easy to install and should give you years of trouble-free service. Here are a few simple instructions to help you get things hooked up right:

Standard Model 531 MF:

1.Unplug (disconnect) the existing connection between the coaxial cable and the equipment I/O port.

2.Install the Model 531 between the incoming coax line and the protected equipment (see below). Place the surge protector as close as possible to the device being protected.

3.Connect the braided ground strap directly to a frame ground connection on the protected device. If you are unsure where to locate a frame ground connection on your equipment, consult the equipment's user manual or contact the manufacturer—the ground connection is critical for proper operation of the Model 531.

Connection to frame

 

 

 

Output to protected

ground

 

 

 

 

 

 

equipment

 

 

 

 

 

 

531

ThinNet

 

Model

 

 

 

Protector

 

Surge

 

 

 

Coaxial input from

Network

T-Splitter Model 531 MFF:

1.Remove the existing T-splitter from the Network Interface Card and disconnect the coaxial cables.

2.Install the Model 531 directly on the Network Interface Card and reattach the coaxial cables.

3

3.Connect the braided ground strap directly to a frame ground connection on the protected device. If you are unsure where to locate a frame ground connection on your equipment, consult the equipment’s user manual or contact the manufacturer - the ground connection is critical for proper operation.

Connection to frame ground

Model 531 ThinNet

Surge Protector

Coaxial input

Coaxial input from

from Network

Network

 

 

4

Page 3
Image 3
Patton electronic user manual Standard Model 531 MF, T-Splitter Model 531 MFF, Insta L L At I O N