features overview 3
rear panel
4Output connections
Speakers can be connected via the high current binding posts and the
Binding posts: One pair (Red- hot, Black- ground) per channel.
Speakons - One connector for each channel.The Speakon connector for Channel A also contains contacts for Channel B out put as well (see Operation Modes).
5Ground lift switch
The recessed
6Input connections
Input signals can be connected to the amp via the Combi connec- tors, the 1/4” TRS connectors, and the Female XLR (pin 2 hot) con- nectors. See Connections
Never connect a speaker of LESS | a | ||
| |||
than 2Ω minimum impedance to an |
| ||
individual channels’ output connections |
| ||
when operating in STEREO or PARAL- |
| ||
LEL mode. |
|
| |
Never connect a speaker of LESS |
| ||
than 4Ω minimum impedance to |
| ||
Channel A and B “+” output connec- |
| ||
tions when operating in BRIDGE |
| ||
mode. In BRIDGE mode operation, the |
| ||
amplifier can produce output voltages |
| ||
exceeding 120VRMS. Use extreme cau- |
| ||
tion. |
|
| |
Never connect a hot | a |
| |
(red) output to ground |
| ||
|
| ||
or to another hot (red) |
|
| |
output! |
|
| |
In situations where an UNBAL- | a | ||
ANCED signal is fed to the amp, it’s | |||
|
important to ground the unused input. If the inverting
7Mode selector switch
This recessed, three position switch configures the amplifier for Stereo, Parallel or Bridged Mono operation. The default factory setting is Stereo. See - operation modes.
a
Do not adjust the mode selection switch while the amplifier is
8Input sensitivity switch
This three position switch allows the user to select the input sensitivity to .775v (0 dBu), X20, or X40 for full rated output power.The default factory setting is X20.
p.13