Installation to Solid Concrete or Cinder Block
WARNING
•When installing Peerless wall mounts on cinder block, verify that you have a minimum of
•Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
•Make sure that the supporting surface will safely support the combined load of the equipment and all attached hard- ware and components.
1 | Make sure that wall plate (AA) is level, use it as a |
template to mark four mounting holes. The top |
mounting hole should be 2.5" above the desired screen center as shown in figure 1.1 on page 4. Drill four 1/4" (6 mm) dia. holes to a minimum depth of 2.5" (64 mm). Insert anchors (DD) in holes flush with wall as shown (right). Place wall plate over anchors and secure with #14 x 2.5" screws (CC). Level, then tighten all fasteners.
WARNING
•Tighten screws so that wall plate is firmly attached, but do not overtighten. Overtightening can damage screws, greatly reducing their holding power.
•Never tighten in excess of 80 in. • lb (9 N.M.).
WARNING
•Always attach concrete expansion anchors directly to
•Never attach concrete expansion anchors to concrete covered with plaster, drywall, or other finishing mate- rial. If mounting to concrete surfaces covered with a finishing surface is unavoidable, the finishing surface must be counterbored as shown below. Be sure concrete anchors do not pull away from concrete when tightening screws. If plaster/drywall is thicker than 5/8", custom fasteners must be supplied by installer.
1 | concrete |
| |
| surface |
|
|
DD
Drill holes and insert anchors (DD).
2 | AA |
|
CC DD
Place plate (AA) over anchors (DD) and secure with screws (CC).
3
Tighten all fasteners.
AA | DD |
CC |
|
|
| INCORRECT |
VIEW | wall | concrete |
plate |
| |
|
| |
CUTAWAY |
| plaster/ |
| dry wall | |
|
|
CORRECT
wall plate | concrete |
| plaster/ |
| drywall |
6 of 9 | ISSUED: |