Pelco BKMT10/230 installation manual C468M INSTALLATION MANUAL, Scope, Installation, Description

Models: BKMT10/230 BKMT10/24

1 2
Download 2 pages 19.69 Kb
Page 1
Image 1
C468M

C468M

INSTALLATION MANUAL

BKMT10,BKMT10/230,ANDBKMT10/24

BLOWER KITS

®

1.0 SCOPE

3.0 INSTALLATION

The information contained within this manual pertains to the BKMT10, BKMT10/230, and BKMT10/24 blower kits.

Installation should be in accordance with all applicable local and national electric codes, utilizing approved materials only.

2.0 DESCRIPTION

The BKMT10, BKMT10/230, and BKMT10/24 are continuous duty blower kits designed for use in either the HT10V or MT10P liquid cooled enclosures.

Install the blower kit in either the HT10V or MT10P enclosure as outlined below.

1.Remove the rear plate of the enclosure, and then remove the camera sled.

2.Assemble blower/blower bracket to sled as shown in Figure 1, items 1–4.

3.Install sled into enclosure.

4.Wire blower to power source using butt splices provided.

5.Re-install rear plate of the enclosure.

2.1 MODELS

BKMT10

Blower kit, 6.7 watts @ 120 VAC,

 

60 Hz, 33 cfm

BKMT10/230

Blower kit, 8.9 watts @ 230 VAC,

 

50 Hz, 27 cfm

BKMT10/24

Blower kit, 1.92 watts @ 24 VDC

 

(AC rectified), 30 cfm

Item

Description

Part Number

1

1/4-20 bolt

ZH1/420X.750SFS

2

Fan bracket

BK40004001COMP

3

Washer

ZH260X562X65C

4

Nut

ZH1/420NUTCHN

5

Fan Securement

 

 

Assembly

 

 

Screw

ZH4-40X.500SPP (Qty. 4)

 

Washer

ZH4LWSIS (Qty. 4)

 

Nut

ZH4-40NUTSH (Qty. 4)

6

Fans

 

 

24 VDC

EH4600105W3

 

120 VAC

EH4600115W3

 

230 VAC

EH4600123W3

Figure 1. BKMT10 Series Blower Kit Installation

REVISION A — 12/93

1

Page 1
Image 1