20 C1528M-F (6/05)
NOTE:
Refer to the
Programming
section for instructions on changing Port settings.
7RJ-45 RS-485 or RS-232 RS-485 Pin-Outs:
1Rx+
2Rx-
5Ground
7Tx-
8Tx+
RS-232 Pin-Outs:
1Rx
5Ground
8Tx
ASCII device CM9760-MDA, Satellite, keyboards
(KBD100/200A/300A)
8RJ-45 RS-485 or RS-232 RS-485 Pin-Outs:
1Rx+
2Rx-
5Ground
7Tx-
8Tx+
RS-232 Pin-Outs:
1Rx
5Ground
8Tx
ASCII device CM9760-MDA, keyboards (KBD100/
200A/300A)
Table C.
Default Port Settings
Port Default Settings
1MGR, RS-232, 56000 baud, no parity, 8 data bits, 1 stop bit
2BAY-TO-BAY, RS-232, 115000 baud, no parity, 8 data bits, 1 stop bit
3M, RS-485, 19200 baud, no parity, 8 data bits, 1 stop bit
4MUX-GENEX, RS-485, 9600 baud, odd parity, 8 data bits, 1 stop bit
5, 6 KBD300, RS-485, 9600 baud, odd parity, 8 data bits, 1 stop bit
7, 8 ASCII, RS-485, 9600 baud, no parity, 8 data bits, 1 stop bit
Table B.
Communication Port Devices and Wiring (Continued)
Port Input Type Wiring Pin-Outs Default Device Programmable to Other Device(s)