[ 6 ] Pelco Manual C2408M-F (4/03)
ADJUSTMENTS (Color Camera Only)
If you have a color camera, it is set up at the factory and normally requires no adjustments. Sometimes,
however, adjustments may be necessary.
1. Remove the cover using the supplied 1/8-inch hollow screwdriver bit.
2. Adjust the vertical phase, iris level, focus, or switch settings (refer to procedures below).
3. Reseat the O-ring on the cover and reinstall the cover.

Vertical Phase

(24 VAC Operation Only)

Adjustment is required if there is vertical roll when
switching between two cameras.
1. Reverse the 24 VAC connections on one camera. If
both cameras are connected to the same trans-
former, this should solve the problem.
2. If reversing the connections does not solve the
problem, or if cameras are connected to different
transformers, turn the adjustment screw (on the
power board on the back of the camera assembly)
on one camera (while switching as rapidly as
possible between the two camera views) until the
switching is clean and there is no vertical roll. If
more than two cameras are out of synchronization
with each other, choose one camera and
synchronize all others to it.
LOCKING
RINGS
If you have a varifocal lens, remove the cover with the supplied 1/8-inch hollow screwdriver bit.
Loosen the focal length and focus locking screws. Adjust according to scene detail. Retighten the
screws. Reseat the O-ring on the cover and reinstall the cover.
CAUTION:
Heater elements
could be hot!
When camera power is on,
use caution when adjusting
the camera. This applies to
all models.
4Adjust Camera
Turn on power to the camera and monitor. Release one or both locking
rings, swivel the enclosure until the angle of the camera is correct, and
tighten the locking rings.