Spectra III SeriesSpectra III SE SeriesProduct Specifications

C2449M-B (7/05)

GENERAL
Construction
Back Box
Surface Mount Plastic
In-Ceiling Aluminum
Pendant Aluminum
Dome Drive Aluminum, thermoplastic
Lower Dome Acrylic
Cable Entry (Back Box)
In-Ceiling/Surface Mount 0.75-inch conduit fitting
Pendant Through 1.5-inch NPT pendant mount
Pan Movement 360° continuous pan rotation
Vertical Tilt Unobstructed +2° to -92°
Manual Pan/Tilt Speeds*
Pan 0.1°- 80°/sec manual operation, 150°/sec turbo
Tilt 0.1°- 40°/sec manual operation
Preset Speeds Spectra III Spectra III SE
Pan 250°/sec 360°/sec
Tilt 200°/sec 200°/sec
*For variable-speed operation an appropriate controller is required. With fixed-
speed controllers, pan/tilt speed is 20°/sec. The CM6700 controller with the
KBD200A keyboard has programmable fixed speeds.
ELECTRICAL (Dome Drive Only)
Input Voltage 18-30 VAC; 24 VAC nominal
Input Power 25 VA nominal (indoor, w/o heater); 70 VA nomi-
nal (outdoor, with heater)
Fuse 1.25 A
Auxiliary Outputs 2 (Spectra III SE only)
Alarm Inputs 7 (Spectra III SE only)
Relay Contacts AUX 1 AUX 2 Output
Type Form C Open collector transistor
output
Voltage Low voltage (<40 V) 32 VDC maximum
Current 2 A maximum 150 mA maximum
Environment
Surface Mount Indoor only
In-Ceiling Indoor
Environmental In-Ceiling Outdoor
Pendant Indoor/Outdoor
Operating Temperature
Surface Mount, and
In-Ceiling Indoor 32° to 122°F (0° to 50°C)
Standard Pendant (Assumes no wind chill factor)
Maximum 140°F (60°C) absolute maximum in shade; 122°F
(50°C) sustained maximum in shade; 113°F (45°C)
absolute maximum in direct sunlight; 95°F (35°C)
sustained maximum in direct sunlight
Minimum 25°F (-4°C) sustained minimum
Environmental In-Ceiling
and Environmental Pendant (Assumes no wind chill factor)
Maximum 140°F (60°C) absolute maximum; 122°F (50°C)
sustained maximum
Minimum -60°F (-51.1°C) absolute minimum; Prevents icing
at sustained minimum of -50°F (-45°C); de-ices
0.1 inch (2.5 mm) within 3 hours after power-up.
Dimensions See figures below
Weight (approximate)
Back Box
Surface Mount 0.7 lb (0.32 kg)
In-Ceiling Indoor 1.5 lb (0.68 kg)
Environmental In-Ceiling 2.1 lb (0.95 kg)
Standard Pendant 2.4 lb (1.09 kg)
Environmental Pendant 3.5 lb (1.59 kg)
Dome Drive 2.4 lb (1.09 kg)
Lower Dome
Surface Mount 0.4 lb (0.18 kg)
In-Ceiling 0.2 lb (0.09 kg)
Pendant 0.6 lb (0.27 kg)
Surface Mount
Standard
Pendant
Environmental
In-Ceiling
Environmental
Pendant

ENGLISH

7.6 (19.3)
8.7
(22.0)
5.9 (15.0)
1.6
(4.0)
5.9 (15.0)
10.6
(26.9)
8.6 (21.8)
4.3
(10.9)
9.9 (25.2)
4.4
(11.0)
5.9 (15.0)
8.9 (22.6)
5.9 (15.0)
10.6
(26.9)
9.30 (23.6)
7.5 (19.0)
5.2
(13.2)
8.2 (20.8)
3.5
(8.8)
5.9 (15.0)
In-Ceiling
Note: Values in parentheses are centimeters; all others are inches.