ELECTRICAL BOX MOUNTING

To install the SWM Series wall mount onto a single gang electrical box (refer to Figure 2 on page 5):

1.Thread the two inner mounting holes on the adjustment plate to be used with threaded mounting fasteners (not supplied).

2.Pull the electrical cables from the gang box through the cable hole in the adjustment plate.

3.Fasten the adjustment plate to the mounting surface with two fasteners of appropriate length and size (not supplied).

4.Pull the electrical cables from the gang box through the cable hole in the mounting cleat. Position the cleat so the elongated mounting fastener hole is below the cable entry hole and the embossed arrow is pointing up.

5.Fasten the mounting cleat to the adjustment plate with two threaded fasteners of appropriate length and size (not supplied).

6.Pull the electrical cables through the mount, hook the mount onto the top of the mounting cleat, and position the mount flush against the mounting surface. If necessary, loosen the set screw to ensure the mount is flush against the mounting surface. Tighten the set screw in the bottom of the mount only until the mount is snug against the surface. Do not overtighten.

7.Attach the pendant model back box to the mount:

a.Pull the electrical cables from the mount into the back box.

b.Apply anti-seize lubricant (supplied) to the back box pipe threads.

c.Screw the back box into the threads in the mount.

d.Complete the installation using the instructions in the dome manual.

MOUNTING CLEAT

MOUNTING FASTENERS (NOT SUPPLIED)

WALL MOUNT

ADJUSTMENT

PLATE

10-24 SET SCREW

Figure 2. Installing the SWM Series Wall Mount onto an Electrical Box