2. Electrical Connections - Follow the correct instructions for your control model.
Cable Distances:
Pan/Tilt
or Scanner Refer to the installation manual for the specific scanner or pan/tilt to be used with the control.
Lens The following lens distances are the approximate maximum recommended under the following conditions:
Based on a 35 mA load @ 12 VDC
Single lens function activation
10% line loss in voltage at the lens motor
22 AWG (0.3 mm2) 1,062 ft (323 m)
20 AWG (0.5 mm2) 1,688 ft (514 m)
18 AWG (1.0 mm2) 2,686 ft (818 m)
MPTAZ24DT and MPTAZ24DT/220 - Wire the connecting cable from the pan/tilt or scanner to the control. Refer to one
of the following wiring diagrams: Figure 2 (scanners) or Figure 3 (pan/tilts). Proceed to step 3.
NOTE: When a relay box (RB24/RB115) is used with a scanner, the AUTO SCAN mode requires special connections;
consult factory for details.