4Pelco Manual C496M (12/90)
4.3 HEATER/BLOWER WIRING
The blower is factory wired to the PCB assembly.
Connect the heaters to the PCB assembly as shown in
the respective wiring diagrams (refer to Figure 2, Fig-
ure 3, or Figure 4).
Supply AC line voltage (230 VAC, 120 VAC, or 24 VAC)
as shown.
4.4 ELECTRICAL CONNECTION
After the cable has been routed, all wire connections
should be made (i.e., video, lens, camera power, heat-
ers). A 6-position terminal block has been provided to
assist in this.
CAUTION: When using a single power
source for both the camera and accessories, the
camera power consumption must be taken into
consideration when determining the wire gauge.
Also, make certain that all electrical connec-
tions are done properly and meet electrical
codes.
Figure 2. HB6000/220 Heater/Blower Kit Wiring Diagram (230 VAC)