4.4 TAMPER SWITCH INSTALLATION

The HS2000 enclosures come standard from the fac- tory with a tamper switch installed. Should it become necessary to install a replacement switch, refer to Fig- ure 1 for the correct position of the bracket/switch and perform the following steps:

1.Remove the front cover.

2.Install the bracket/switch and secure with lockwashers and nuts.

4.5 TAMPER SWITCH WIRING

The tamper switch comes with both a “Normally Open” and a “Normally Closed” contact.

For a “Normally Open” circuit, use the “open” and “common” terminals; for a “Normally Closed” circuit, use the “closed” and “common” terminals.

5.0 CARE AND MAINTENANCE

Maintenance performed at regularly scheduled inter- vals will help prolong the operational life and appear- ance of the equipment.

1.Clean the Lexan window with a mild non-abra- sive detergent in water and a soft cloth regularly to help maintain picture clarity. For a heavily soiled window, use vinyl cleaner.

NOTE: Pelco offers a 24-hour, seven-day-a week Technical Assistance Program (TAP) de- signed to assist any customer with a technical problem involving Pelco equipment whether it’s the weekend or late at night. For technical as- sistance dial (800) 289-9100 and you will be connected to a Pelco TAP member who is trained to answer your questions.

Pelco also guarantees one-day turnaround on any Pelco equipment sent in for repair. This includes warranty and non-warranty items. Refer to the section on “Warranty and Return Information” in this manual for the proper pro- cedure.

Figure 1. HS2000 Series Tamper Switch Installation

4

Pelco Manual C494M-D (1/96)

Page 6
Image 6
Pelco HS2000 operation manual Tamper Switch Installation, Tamper Switch Wiring, Care and Maintenance