Pelco Manual C655M (6/99) 5

OUTPUT CONNECTIONS

Perform the following steps to attach 24 VAC devices to the MCS*E Series power supply:
1. Refer to Tables C and D in this manual or the wiring table on the unit’s lid to determine
the output connection needed for your devices.
2. Refer to Figure 1 for the proper connector strip connections.
3. For each device, attach one output wire to the common terminal. Attach the second
wire to the appropriate 24 VAC terminal.
4. When you finish the wiring connections, double check the installation for safety pur-
poses.
5. Power up the unit with the on/off switch.
6. Use a voltmeter to verify that used outputs are at appropriate voltage levels.
7. Close the lid and secure it using the 8-32 Phillips screw.
Figure 1. MCS*E Series Unit Wiring Connector Diagram
1234 5678 9101112
OUTPUT 1 THRU 8 OUTPUT
9

ON

OFF

Power
Main Fuse
24VCOM