Pelco Manual C616M-B (11/97) 7

Sensitivity (SEN) This control adjusts the sensitivity of the detection area
window. Clockwise rotation of a screwdriver on this control
increases sensitivity.
Visual Alert LED
(ALRT) When no motion is detected, the red LED is constantly on
(the ARM toggle switch is in the [ON] up position). The LED
is off when the ARM toggle switch is in the (OFF) down
position. The LED flashes on and off when motion has been
detected, regardless of the ARM switch position.
ARM (ON/OFF) Activates (switch up position) or deactivates (switch down
position) the relay, logic output, and audible alert functions
of the motion detector. It must be in the activated ON
position (switch up) when these functions are desired.
Power On LED (PWR) Green LED lights when power is applied to the unit.

4.2 REAR PANEL CONTROLS AND CONNECTIONS

Refer to Figure 2 to better understand the rear panel controls and connections.
Power
(12 VAC PWR) Input power for the unit.
Video (IN/OUT) The video input (IN) BNC connects the camera to the MD2001.
The video output (OUT) BNC connects the MD2001 to a
monitor or switcher.
6-Pin Connector The 6-pin connector connects external wires to the MD2001.
(See Sections 3.3, 3.4, and 3.5.)
Dip Switch 1-3
(AUTO TIME) Setting dip switches 1-3 define the approximate time for an
alert condition to clear (see Table B, Setup Timer Table and
Figure 3, Dip Switch settings).
Dip Switch 4
(AUDIBLE) Setting dip switch #4 in the up (on) position activates the audible
buzzer and setting #4 in the down position deactivates the
audible buzzer (See Figure 3, Dip Switch settings).
Display Adjustment
(DISP ADJ) Adjusts the detection area window outline from white to gray. To
adjust, turn the display adjustment counter clockwise for white
or clockwise for black.