6Pelco Manual C820M-D (1/01)
LOOPING SWITCHERS
Use coaxial cable to connect the input and looping video cables to the appropriate input
connectors. Connect the monitor(s) to the monitor output. (Refer to Figures 3 and 4.)
IMPORTANT:

Looping

switchers do not have inter-

nal termination. Inputs must

be terminated at 75 ohms by

other equipment in the

system.

Figure 3. MS500 Series Switchers - Looping Configuration

Figure 4. MS500 Series Switchers - Looping Configuration with Coaxitron Transmitter

CAMERA
MON
4321
AC INPUT
UN-TERMINATED
MONITOR
(SWITCH IN THE
HI-Z POSITION)
CAMERA
MON
4321
AC INPUT
MS504LDT (REAR VIEW)MS504DT (REAR VIEW)
TERMINATE
MONITOR
(SWITCH IN THE
75 POSITION)
CAMERA
MON
4321
AC INPUT
COAXITRON
TRANSMITTER
UNTERMINATED
TRANSMITTER
TERMINATE
MONITOR
(SWITCH IN THE
75 POSITION)
CAMERA
MON
4321
AC INPUT
COAXITRON
TRANSMITTER
TERMINATE
MONITOR
(SWITCH IN THE
75 POSITION)
MS504LDT(REAR VIEW)MS504DT(REAR VIEW)
TERMINATE LOOPING
OUTPUT AT 75