22 Pelco Manual C1995M-A (10/01)
PROGRAMMING
Programming of setups for system, camera, VCR, camera sequencing, and alarm handling
is done through on-screen menus displayed on the main monitor.
There are two ways to program the multiplexer:
• From the multiplexer front panel. This section provides detailed information.
•From the KBD4000/KBD4002/KBD4000V keyboard. Follow the instructions in your
keyboard manual, or refer to the
Specific Applications Programming
section in this
manual.
CODE FILE PROGRAMMING SWITCH
An unlabelled switch on the multiplexer’s rear panel is for factory use only. It is used for
programming code files. In the up (OFF) position it prevents changes; in the down (ON)
position it allows programming. The switch is located to the right of the termination DIP
switches.
PASSWORD
You can program the multiplexer to request a password to access programming menus.
Enable the password in the Advanced System Setup menu (refer to the
Advanced System
Setup [View Button]
section).
The universal password is 4212 and cannot be changed. You must enter this password by
pressing the camera number keys whenever a password is requested.
NOTE:
Whenever a multi-
plexer server is installed, you
must enter programming
mode from the multiplexer’s
front panel. After doing so,
you can program the multi-
plexer through its front panel
or you can navigate and
make programming selec-
tions through the keyboard.