Installation

ENCLOSURE DISASSEMBLY

1.Disconnect power to the enclosure.

2.Remove the ground wire from the ground stud on the back of the enclosure.

3.Remove the electrical connector from the rear of the enclosure by turning the outer ring counterclockwise and pulling the mating portion of the connector off.

4.You may remove the enclosure from its mount to make the installation process easier.

5.Remove the cap from the Schraeder valve (refer to Figure 1).

6.Relieve internal enclosure pressure by depressing the center stem of the Schraeder valve.

CAUTION: Pressure must be released prior to opening the enclosure or personal injury may result.

7.Remove the rear plate of the enclosure (refer to Figure 1) and do the following:

a.Use a screwdriver to pry the end of the spiral retaining ring from the retaining ring groove.

b.Pull on the “T” handle to remove the rear plate from the housing.

 

SCHRAEDER

RETAINING

VALVE

SPRING

PRESSURE

END

RELIEF VALVE

GROUND STUD

SPIRAL

RETAINING

SPRING

T-HANDLE

Figure 1. EH8100 Series Enclosure - Rear View

6

C1445M-D (11/04)

Page 6
Image 6
Pelco PSKIT8100 manual Installation, Enclosure Disassembly