
Figure 2. Connector Assembly
3.3 CONNECTOR ASSEMBLYInstallation and/or testing will require you to assemble the connector parts pro-
vided. Fabricate the interconnecting cable according to the following steps (refer-
ence Figure 2).
1. Slide part A of the cable clamp (item 1) over the end of the cable (item 1, part
C) with the threaded end of the cable clamp facing the connector (item 5).
2. If the cable has a diameter less than 1/2 inch (1.3 cm), slide the rubber boot
(item 2) over the end of the cable and pull through the cable clamp to so that
the boot encases the cable and forms a good seal.
3. Strip back the cable jacket approximately 1-1/4 inches (3.2 cm) and separate
the individual conductors (item 3).
4. The contact pins supplied with the mating connector are the “crimp” type which
may also be soldered if you so desired (item 4).
5. After crimping or soldering the contact pins to the conductors, push them into
the proper holes in the connector until they snap in place.
6. Slide part A of the cable clamp toward the connector and screw the parts
together. Attach part B (item 1) onto part A and connect both parts with the
screws provided.
7. Connect the cable assembly to the unit and seat the connector by twisting the
locking collar until it snaps into position.