24 Pelco Manual C652M (7/99)
REC MODE Sets the recording mode.
NORMAL<SP> – Choose SP (standard play) when higher
picture quality is desired. With this setting, the recording
time mode is switched in the following order: 2H, L24H,
48H, 72H, 96H, 120H, 168H, 0H, 2H.
H•D<EP> – Select the EP (extended play) setting to make
high density recording. This provides three times more
fields than normal density (SP). It reduces the time interval
between pictures, providing more pictures for smoother
time-lapse recording. With this setting, the recording time
mode is switched in the following order: 6H, L18H, 48H,
72H, 96H, 120H, 168H, 0H, 6H.
ONESHOT•FIELD Sets the number of fields to record in the one-shot mode. When
you turn the JOG dial to the right, the display switches in the
following order: 1, 2, 3, 4, 5, 10, 20, 30, 1. The default is 1.
ONESHOT• Sets the interval time in one-shot mode. When you turn the
INTERVAL JOG dial to the right, the display switches in the following order:
SHOT, 10S (second), 15S, 30S, 45S, 1M, 2M, 3M, SHOT. The
default is SHOT.
6.8 REAR TERMINAL MENU
CALL OUT Sets the call signal output at the end of the tape. Turns on or off
the signal that comes from the CALL terminal when the end of
the tape is reached during recording. If any problems occur
during recording, a call signal is output from the CALL terminal
on the rear panel regardless of the CALL OUT setting. The
default is WRNG•TAPE END.
WRNG•TAPE END – A signal is output at the end of the
tape or when a malfunction occurs.
WRNG•REMAIN – The signal is output when a malfunc-
tion occurs in the VCR or when the tape has about three
minutes left in 2H mode.
WRNG – When a malfunction occurs in the VCR during
recording, a call signal is output.
CALL OUT is used in conjunction with TAPE END (First Time
Set Up menu) to determine when the call signal is output, as
shown in Table B.
Figure 13. Rear Terminal Menu
Table B. Call Out/Tape End
CALL OUT
TAPE END setting WRNG•TAPE END WRNG•REMAIN WRNG
setting
STOP
REWIND
REPEAT (same as above)
(same as above)
ALARM
•PROT
Outputs a call signal at the
end of the tape.
Outputs a call signal 3 minutes
before the end of the tape
(same as above)
(same as above)
(same as above)
(same as above)
When a malfunction occurs in
the VCR during recording, a call
signal is output
(same as above)
(same as above)
(same as above)
(same as above)
Outputs a call signal at the
end of the tape for 2 seconds.
When there are no
alarm recordings
during recording.
When there are alarm
recordings during
recording.
Outputs a call signal at the
end of the tape.
<
REAR TERMINAL
>
WRNG•TAPE END
REC- 1
REC
SERIES
CALL OUT
CLOCK OUT
MODE OUT
REC IN