PELICANTM

M10 8040

INSTRUCTIONS

CATALOG # 8040

23215 Early Ave. • Torrance, CA 90505 USA Tel (310) 326-4700 • FAX (310) 326-3311 www.pelican.com

PELICAN LEGENDARY LIFETIME GUARANTEE OF EXCELLENCE

Pelican Products, Inc. guarantees its products for a lifetime against breakage or defects in workmanship. This guarantee does not cover the lamp or batteries (rechargeable or alkaline). Any liability, either expressed or implied, is limited to replacement of the product. This guarantee is void if the Pelican product has been abused beyond normal and sensible use. This guarantee does not cover shark bite, bear attack or damage caused by children under five.

Lifetime Guarantee does not cover Roto Molded or AALG products. Refer to www.pelican.com/warranty for full details.

LA LEGENDARIA GARANTÍA DE EXCELENCIA DE POR VIDA DE PELICAN Pelican Products, Inc. garantiza sus productos de por vida contra roturas o defectos de fabricación. Esta garantía no cubre la lámpara ni las pilas (recargables o alcalinas). Cualquier responsabilidad, expresa o implícita, está limitada a la sustitución del producto. Esta garantía quedará anulada en caso de haberse realizado un uso fuera de lo normal y razonable del producto Pelican. Esta garantía no cubre mordiscos de tiburones, ataques de osos ni daños producidos por niños menores de cinco años.

La Garantía de por vida no cubre los productos rotomoldeados ni los productos del AALG. Más información en www.pelican.com/warranty.

GARANTIE D’EXCELLENCE À VIE LÉGENDAIRE DE PELICAN

Pelican Products, Inc. garantit ses produits pendant la durée de vie utile contre toute rupture ou défaut de fabrication. Cette garantie ne couvre pas les ampoules ni les batteries (alcalines ou rechargeables). Toute responsabilité, qu’elle soit expresse ou implicite, est limitée au remplacement du produit. Cette garantie sera considérée comme nulle si le produit Pelican a fait l’objet d’un usage excessif en dehors de l’usure et de la déchirure normales et raisonnables. Cette garantie ne couvre pas les morsures de requin, les attaques d’ours ni les dommages causés par des enfants de moins de 5 ans.

La garantie à vie ne couvre pas les produits moulés Roto ou AALG. Consultez la page Web www.pelican.com/warranty pour les détails complets

23215 Early Ave. • Torrance, CA 90505 USA

Tel (310) 326-4700 • FAX (310) 326-3311 • www.pelican.com

PELICANTM CANADA

10221-184 St. • Edmonton, Alberta T5S 2J4

Tel (780) 481-6076 • FAX (780) 481-9586

PELITM PRODUCTS, S.L.U.

c/ Casp, 33-B Pral. • 08010 • Barcelona, Spain

Tel (+34) 93.467.4999 • FAX (+34) 93.487.7393 • www.peli.com

8043-312-000 5-0697 Rev A © 2010 Pelican Products AU/10

All trademarks are registered and/or unregistered trademarks of

Pelican Products, Inc. its subsidiaries and/or affliates.

Energizer is a registered trademark of Eveready Battery Company, Inc.

M10 8040

OPERATING INSTRUCTIONS CAT. #8040

PLEASE READ!

VERY IMPORTANT SAFETY INSTRUCTIONS Before disassembling any part of the M10 flashlight, ensure that the flashlight has not been operating for five (5) minutes prior to replacing the lamp module. During operation, the lamp module can become ex- tremely hot and may cause injury if touched.

BATTERY INSTALLATION

1.Remove the end cap by turning counter-clockwise.

2.Remove used batteries and replace with fresh batteries as shown by the polarity sticker.

3.To replace the end cap place end cap squarely on threads and turn clockwise while pressing on the end cap slightly.

ON/OFF

1.For MOMENTARY operation gently press down on

the rubber switch cover of the flashlight and the M10 will operate until pressure is released.

2.For CONTINUAL operation press firmly down on the rubber switch cover until a “click” is heard and release .

To turn off press down on the switch cover again until a “click” is heard and release.

LAMP REPLACEMENT

1.Allow flashlight to remain off for 5 minutes prior to lamp replacement.

2.Unscrew the lens assembly.

3.Remove the lamp module and replace with a new lamp module.

4.Replace the lens cover assembly.

HYDROGEN GAS ABSORBER

Internal catalyst pellets, located on the lamp, are there to help absorb hydrogen gas that could possibly be emitted by defective, leaking, reversed polarity or heavily discharged batteries. If the pellets become lost or damaged, replace lamp immediately. If pellets become wet, let them air dry or replace. Pelican Products assumes no liability for any brand batteries which are defective or cause injury to anyone when used in any Pelican flashlight.

Do not mix battery brands or use Nicad or Zinc Carbon batteries or old/new batteries.

WARNING – Explosion Hazard - Batteries must only be changed in non-hazardous locations.

WARNING – Explosion Hazard - Substitution of components may impair suitability for use in hazardous locations.

WARNING – STATIC HAZARD -

Clean only with a damp cloth

O-RING MAINTENANCE

Check closely for cuts, scratches, or otherwise damaged O-ring or mating lens lip surface. Remove any dirt or foreign matter from O-ring sealing surfaces. Keep threads, O-ring groove and inside lip of lens lubricated with silicone grease. See Warranty information for replacement of O-ring.

PRODUCT SPECIFICATIONS

Lamp Type:

Xenon

Lamp Life:

30 hours

Battery Type:

1.5V “C” Alkaline (4-cell)

Battery Brand:

Energizer®

REPLACEMENT PARTS

CAT. #

DESCRIPTION

8051

O-Ring

8044

Xenon Lamp

WARRANTY RETURN POLICY

Send all items for repair or replacement directly to Pelican Products Customer Service Department (postage paid). Please call for a return authorization number. Per our guarantee, Pelican Products will replace or repair any broken or defective products. Upon receipt of goods, Pelican Products will notify you of any handling and return postage charges. If your local retailer does not stock the above accessory parts, you may or- der them directly from Pelican Products. Send check or money order in U.S. dollars, or order by phone using MasterCard or VISA (ask for Customer Service). SORRY, NO C.O.D.’s. Subject to sales tax. Allow 2-3 weeks delivery time. Pelican Products pays postage and handling charges.

Page 1
Image 1
Pelican M10 8040 operating instructions Battery Installation, On/Off, Lamp Replacement, Hydrogen GAS Absorber