3

Plumbing Requirements

It is important that the pool and spa plumbing system be in accordance with local codes and the Recommended Hydraulic Schematics (page 4 and 5). Before starting, please review the diagrams and the following recommended guidelines:

1The spa should be at or above the level of the pool.

If the spa is attached to the pool, provide a dam between the two bodies of water to allow the spa to overflow into the pool. If the spa is not attached to the pool, an overflow, sufficient in size to carry a full pump-flow, must be installed at the water level in the spa.

2Plumb a three-port Intake Valve on the suction-side of the filter pump, so that the center port of the valve is connected to the pump inlet. Connect the spa suction to one side of the Intake Valve, and the pool suction to the other side.

3Plumb a three-port Return Valve on the return-side of the heater, so that the return water will enter the valve through the center port.

Connect the spa return to one side of Return Valve, and the pool return to the other side.

4If required, install a spa makeup line (consisting of a manual gate or ball valve, for elevated spas install a check valve) to bypass the pool return line. This will enable some of the chemically- balanced water from the pool to cycle through the spa. The manual valve will allow the amount of bypass to be adjusted.

5If the spa is to be constructed in concrete, special provision should be made at this time for the installation of the Spa-Side remote control.

Select a convenient location in the deck or above water level in the spa wall (where the Spa-Side remote will not be submerged by the spa water), and install a 6 in to 12 in length of one inch PVC pipe to provide a receptacle for the Spa-Side remote. The pipe should be level and protrude beyond the finished surface of the spa. It will be cut back later at installation time. Reduce the pipe size down to ½ in or ¾ in conduit, and run it to the proposed Load/Power Center location at the equipment pad. Use sweep elbows for turns.

The Spa-Side remote will not be installed until the spa construction is completed.

6For systems which incorporate a skimmer, it is possible to balance the amount of suction between the skimmer and main drain for maintenance purposes. This is easily accomplished by installing a manual three-port mixing valve at the suction line. Plumb one port to the skimmer and the other to the main drain.

7If a “non-booster pump” pressure-side pool cleaner is being used, plumb a manual three-port valve between the filter pump and filter, with the third port plumbed to the pool cleaner line, and install a motorized two-port Pool Cleaner Valve at this line. The motorized valve will automatically open whenever the Control System activates the pool cleaner.

8If a booster pump pool cleaner is being used, plumb the booster pump so that its suction-side is connected to the pool return, after the heater, and as close to the ground as practical.

EasyTouch Load Center Installation Guide

Page 9
Image 9
Pentair 8 and 4 important safety instructions Plumbing Requirements

8 and 4 specifications

Pentair is renowned for its innovative solutions in water and fluid management, and the Pentair 8 and 4 series are prime examples of their commitment to delivering high-performance products. These series are designed for both residential and commercial applications, showcasing advanced features and technologies that cater to diverse needs.

The Pentair 8 series is known for its robust performance and reliability. It incorporates a powerful motor designed to ensure efficient water circulation and filtration. The 8 series stands out with its user-friendly interface, enabling effortless adjustments and monitoring. The built-in diagnostic features provide real-time feedback, ensuring users can maintain optimal operation without ongoing manual checks. Additionally, the Pentair 8 series emphasizes energy efficiency, reducing power consumption and lowering operational costs.

On the other hand, the Pentair 4 series focuses on compactness and versatility. It is engineered to fit in tight spaces, making it an ideal choice for urban environments where space is a premium. Though smaller in size, the 4 series does not compromise on performance. It utilizes innovative pump technology that maximizes flow while minimizing noise levels. This feature is particularly beneficial for residential applications, where maintaining a quiet environment is essential. The 4 series also includes a range of customizable options, allowing users to tailor the system to their specific requirements.

Both the 8 and 4 series share a commitment to durability and longevity. They are constructed with high-quality materials designed to withstand harsh environmental conditions. This durability reduces the frequency of maintenance and replacement, ultimately providing better value to users.

In summary, the Pentair 8 and 4 series offer a blend of performance, efficiency, and adaptability. Their advanced features, such as energy-efficient motors, user-friendly interfaces, and robust construction, make them suitable for a variety of applications. Whether for residential or commercial use, Pentair continues to set the standard in water management solutions, ensuring both convenience and peace of mind for users. To meet the diverse needs of its clientele, Pentair consistently innovates, ensuring their products remain at the forefront of technology and sustainability.