SYSTEM START-UP
Apply power to the system.
At the LX-30 Power Center, check that the POWER Status Light has turned on.
If the status light is not on, check the 3 amp circuit breaker which is located above
the faceplate. Tripped circuit breaker is indicated by a white tab. Push to reset.
Turn the FILTER PUMP Service Switch "ON" and "OFF to verify that pump is
operating.
Return FILTER PUMP Service Switch to "TIMER" position, and activate filter
7ump using the FILTER TIMER Dial.
t
the system incorporates a pool cleaner pump, activate pump using the
CLEANER TIMER Dial.
At the Remote Control, turn SPA Switch to "SPA position.
Check that Valve Actuators have rotated to correct positions. If either valve is
180" out of phase, flip toggle switch on rear of Valve Actuator from "ON1" to
"ON2" position.
Turn HEAT Switch to "SPA position, and check that heater has been activated.
Turn AUXl and AUX2 Switches "ON", and verify that auxiliary equipment has
been activated.
The system is now ready to be operated as desired.
a
PAC FA6 Company
Cornpool, Inc. 599 Fairchild Drive Mountain View California 94043 800-458-2201 http ://www.c0mpo01.com INSTALLATION INSTRUCTIONS

CP30 POOL-SPA SWITCHING SYSTEM

IMPORTANT SAFETY INSTRUCTIONS
All wiring must be performed by a qualified electrician. Basic safety precautions and local codes should always be followed when installing and using this electrical equipment.

READ AND FOLLOW ALL INSTRUCTIONS.

WARNING
: To reduce the risk of injury, do not permit children to use this product unless they are closely supervised at all times.

SAVE THESE INSTRUCTIONS.