Pentair important safety instructions B. The Pump Strainer Basket

Models: Pump

1 10
Download 10 pages 26.11 Kb
Page 3
Image 3
B. The Pump Strainer Basket.

6.Permanently ground the motor using the green ground terminal located on the inside of the motor canopy or access plate, see Figure 1. Use the correct wire size and type specified by National Electrical Code. Make sure the ground wire is connected to an electrical service ground.

7.Bond the motor to the pool structure in accordance with the National Electrical Code. Use a solid No. 8 AWG or larger copper conductor. Run a wire from the external bonding to the pool bonding structure, see Figure 1.

8.Connect the pump permanently to a circuit. Make sure no other lights or appliances are on the same circuit.

Bonding Lug

Ground Screw

Figure 1.

NOTE

It is important that the O-ring be kept clean and well lubricated. We recommend a silicone base lubricant for best results.

B. The Pump Strainer Basket.

This unit, sometimes referred to as the ‘Hair and Lint Pot’, is the unit in front of the volute. Inside the chamber is the basket which must be kept clean of leaves and debris at all times. View basket through the ‘See Through Lid’ to inspect for leaves and debris.

Regardless of the length of time between filter cleaning, it is most important to visually inspect the hair and lint pot basket at least once a week. A dirty basket will reduce the efficiency of the filter and heater and also put an abnormal stress on the pump motor which would result in a costly repair bill.

SECTION II. MAINTENANCE.

Manual backgroundCAUTION

To prevent damage to the pump and filter and for proper operation of the system, clean pump strainer and skimmer baskets regularly.

A. Pump Strainer Basket Cleaning Procedures.

1.Turn off motor.

2.Relieve pressure in the system.

3.Turn the clamp and lid in a counter-clockwise direction until it stops.

4.Turn the clamp and lid set to remove the clamp and lid.

5.Put the debris from the basket into the trash and rinse out the basket. If the basket is cracked, it should be replaced.

6.Replace the basket and fill the pump pot and volute up to the inlet port with water.

7.Clean the cover, cover O-ring, and sealing surface of the pump pot. Grease the O-ring with Teflon or silicone.

8.Reinstall the lid by placing the clamp and the lid on the pot; see Figure 2.

a. Make sure the lid O-ring is properly placed. Seat the clamp and lid then turn clockwise until the handles are horizontal; see Figure 3.

9.Turn the power “ON” at the house circuit breaker. Reset the pool time clock to the correct time.

Rev. D 6-5-01

3

Clamp, pot

Lid

O-ring, lid

Basket

Pot

Figure 2.

P/N 071109

Page 3
Image 3
Pentair important safety instructions B. The Pump Strainer Basket