Pentair SuperMax Wiring Installation, cont.’d, The Pump Strainer Basket, Ground Screw

Models: SuperMax

1 20
Download 20 pages 40.53 Kb
Page 10
Image 10
Wiring Installation, cont.’d.

4

Wiring Installation, cont.’d.

6.Permanently ground the motor using the green ground terminal located on the inside of the motor canopy or access plate, see Figure 1. Use the correct wire size and type specified by National Electrical Code. Make sure the ground wire is connected to an electrical service ground.

7.Bond the motor to the pool structure in accordance with the National Electrical Code. Use a solid No. 8 AWG or larger copper conductor. Run a wire from the external bonding screw on the motor to the pool bonding structure.

8.Connect the pump permanently to a circuit. Make sure no other lights or appliances are on the same circuit.

NOTE

It is important that the O-ring be kept clean and well lubricated. We recommend a silicone base lubricant for best results.

The Pump Strainer Basket

This unit, sometimes referred to as the ‘Hair and Lint Pot’, is the unit in front of the volute. Inside the chamber is the basket which must be kept clean of leaves and debris at all times. View basket through the ‘See Through Lid’ to inspect for leaves and debris.

Regardless of the length of time between filter cleaning, it is most important to visually inspect the hair and lint pot basket at least once a week. A dirty basket will reduce the efficiency of the filter and heater and also put an abnormal stress on the pump motor which would result in a costly repair bill.

Ground Screw

Figure 1.

SuperMaxPump Installation and User’s Guide

Page 10
Image 10
Pentair SuperMax important safety instructions Wiring Installation, cont.’d, The Pump Strainer Basket, Ground Screw